API Reference
Heat Pump Web API
The integration communicates with the heat pump's embedded web server.
Get Status
Retrieves current heat pump status and sensor readings.
Endpoint:
GET /installedplugin/com.innova.pdc/<VERSION>/server/index.php?Action=GetStatus
Response:
{
"sw": { "V": "3.0.49" },
"success": true,
"model": "RDZ",
"RESULT": {
"TSLastUpdate": 1759138628,
"info": {
"datetime": "29/09/2025 12:37"
},
"status": {
"ISP": "34.3 °C",
"SSP": 47.0,
"watert1": 32.1,
"watert2": 32.0,
"dhwt3": 46.8,
"t4": 9.6,
"watersetpoint": 43.0,
"dhwsetpoint": 47.0,
"heating": true,
"cooling": false,
"pwr": false,
"san": false,
"pump": true,
"res": false,
"standby": false,
"sce": true,
"alarm": {
"status": false,
"type": "",
"label": ""
},
"worktime_pdc": 11614,
"worktime_res": 593
}
}
}
Status Fields
| Field | Type | Description |
|---|---|---|
ISP |
string | Inlet Setpoint (e.g., "34.3 °C") |
SSP |
float | System Setpoint |
watert1 |
float | Inflow water temperature |
watert2 |
float | Outflow water temperature |
dhwt3 |
float | Domestic hot water temperature |
t4 |
float | Outdoor temperature |
watersetpoint |
float | Water temperature setpoint |
dhwsetpoint |
float | DHW temperature setpoint |
heating |
bool | Heating mode active |
cooling |
bool | Cooling mode active |
pwr |
bool | Compressor running |
san |
bool | DHW mode active |
pump |
bool | Circulation pump active |
res |
bool | Auxiliary heater active |
standby |
bool | Standby mode |
sce |
bool | Smart Consumer Electronics |
alarm.status |
bool | Alarm active |
alarm.type |
string | Alarm type code |
alarm.label |
string | Alarm description |
worktime_pdc |
int | Compressor runtime (hours) |
worktime_res |
int | Aux heater runtime (hours) |
Set Parameter
Sets a heat pump parameter (temperature setpoint).
Endpoint:
POST /installedplugin/com.innova.pdc/<VERSION>/server/index.php?Action=SetParameter
Content-Type: application/x-www-form-urlencoded
Parameters:
| Parameter | Type | Required | Description |
|---|---|---|---|
Key |
string | Yes | Parameter name: watersetpoint or dhwsetpoint |
Value |
string | Yes | Temperature value |
manual |
string | Yes | Duration: forever or time-based |
Example:
curl -X POST "http://192.168.1.100/installedplugin/com.innova.pdc/2.0.10/server/index.php?Action=SetParameter" \
-H "Content-Type: application/x-www-form-urlencoded" \
-d "Key=watersetpoint&Value=45&manual=forever"
Response: HTTP 200 on success
Home Assistant Services
rdz_innova_heatpump.set_water_setpoint
Manually set the heating water temperature setpoint.
Service Data:
| Attribute | Type | Required | Description |
|---|---|---|---|
temperature |
float | Yes | Target temperature (35-60°C) |
duration |
string | No | Duration: "forever" (default) or time-based |
Example YAML:
service: rdz_innova_heatpump.set_water_setpoint
data:
temperature: 45
duration: forever
Example Automation:
automation:
- alias: "Set water temperature on schedule"
trigger:
- platform: time
at: "06:00:00"
action:
- service: rdz_innova_heatpump.set_water_setpoint
data:
temperature: 45
duration: forever
Entities
Climate Entity
Entity ID: climate.heat_pump_water_temperature
Attributes:
| Attribute | Description |
|---|---|
current_temperature |
Current water temperature (T1) |
temperature |
Target temperature setpoint |
hvac_mode |
Current mode: heat, cool, off |
hvac_action |
Current action: heating, cooling, idle, off |
min_temp |
Minimum setpoint (35°C) |
max_temp |
Maximum setpoint (60°C) |
target_temp_step |
Temperature step (0.5°C) |
Supported Features:
TARGET_TEMPERATURE
HVAC Modes:
heat- Heating modecool- Cooling modeoff- Standby
Water Heater Entity
Entity ID: water_heater.heat_pump_dhw
Attributes:
| Attribute | Description |
|---|---|
current_temperature |
Current DHW temperature (T3) |
temperature |
Target DHW setpoint |
operation_mode |
on when DHW active, off otherwise |
min_temp |
Minimum setpoint (35°C) |
max_temp |
Maximum setpoint (60°C) |
Sensor Entities
| Entity ID | Unit | Description |
|---|---|---|
sensor.heat_pump_inlet_setpoint_temperature |
°C | ISP value |
sensor.heat_pump_system_setpoint_temperature |
°C | SSP value |
sensor.heat_pump_water_temperature_t1 |
°C | Inflow temperature |
sensor.heat_pump_outflow_temperature_t2 |
°C | Outflow temperature |
sensor.heat_pump_dhw_temperature_t3 |
°C | DHW temperature |
sensor.heat_pump_outdoor_temperature_t4 |
°C | Outdoor temperature |
sensor.heat_pump_water_setpoint |
°C | Water setpoint |
sensor.heat_pump_dhw_setpoint |
°C | DHW setpoint |
sensor.heat_pump_runtime |
h | Compressor hours |
sensor.heat_pump_auxiliary_heater_runtime |
h | Aux heater hours |
sensor.heat_pump_software_version |
- | Firmware version |
Binary Sensor Entities
| Entity ID | Device Class | Description |
|---|---|---|
binary_sensor.heat_pump_heating |
heat | Heating mode |
binary_sensor.heat_pump_cooling |
cold | Cooling mode |
binary_sensor.heat_pump_working |
running | Compressor active |
binary_sensor.heat_pump_dhw_mode |
running | DHW mode |
binary_sensor.heat_pump_water_pump |
running | Pump active |
binary_sensor.heat_pump_auxiliary_heater |
heat | Aux heater active |
binary_sensor.heat_pump_standby |
power | Standby mode |
binary_sensor.heat_pump_disabled_prod |
power | Production disabled |
binary_sensor.heat_pump_sce |
power | SCE active |
binary_sensor.heat_pump_alarm |
problem | Alarm active |
Internal Data Structure
The coordinator maintains this internal data structure:
{
"software_version": "3.0.49",
"last_update": 1759138628,
"datetime": "29/09/2025 12:37",
# Temperatures
"inlet_setpoint_temp": 34.3,
"system_setpoint_temp": 47.0,
"water_temp_t1": 32.1,
"water_temp_t2": 32.0,
"dhw_temp_t3": 46.8,
"outdoor_temp_t4": 9.6,
"water_setpoint": 43.0,
"dhw_setpoint": 47.0,
"aux_heater": 0,
# States
"is_heating": True,
"is_cooling": False,
"is_working": False,
"is_dhw": False,
"is_pump_active": True,
"is_aux_heater": False,
"is_standby": False,
"disabled_prod": False,
"sce": True,
# Runtimes
"worktime_pdc": 11614,
"worktime_res": 593,
# Alarms
"has_alarm": False,
"alarm_type": "",
"alarm_label": ""
}
Access in custom code:
coordinator = hass.data[DOMAIN][entry.entry_id]
temp = coordinator.data.get("water_temp_t1")