202 lines
5.6 KiB
Markdown
202 lines
5.6 KiB
Markdown
---
|
|
layout: default
|
|
title: Troubleshooting
|
|
nav_order: 5
|
|
---
|
|
|
|
# Troubleshooting
|
|
|
|
## Common Issues
|
|
|
|
### Integration Not Appearing
|
|
|
|
**Symptoms:** After copying files and restarting, "Heat Pump Monitor" doesn't appear in the integrations list.
|
|
|
|
**Solutions:**
|
|
1. Verify the folder structure is correct:
|
|
```
|
|
custom_components/
|
|
└── rdz_innova_heatpump/
|
|
├── __init__.py
|
|
├── manifest.json
|
|
└── ... other files
|
|
```
|
|
2. Check file permissions
|
|
3. Perform a full restart (not just reload)
|
|
4. Check Home Assistant logs for errors
|
|
|
|

|
|
*Check Home Assistant logs for error messages*
|
|
|
|
### Connection Failed
|
|
|
|
**Symptoms:** "Failed to connect" error during setup.
|
|
|
|
**Solutions:**
|
|
1. Verify the URL is accessible from your HA server:
|
|
```bash
|
|
curl http://YOUR_HEAT_PUMP_IP/installedplugin/com.innova.pdc/VERSION/server/index.php?Action=GetStatus
|
|
```
|
|
2. Check network connectivity between HA and heat pump
|
|
3. Verify the URL format is correct
|
|
4. Check if heat pump web interface is responding
|
|
|
|
### Missing Sensors
|
|
|
|
**Symptoms:** Some sensors show "Unknown" or "Unavailable".
|
|
|
|
**Solutions:**
|
|
This is often due to firmware version differences. Different versions have different JSON structures.
|
|
|
|

|
|
*Some sensors may show unavailable due to firmware differences*
|
|
|
|
## Firmware Version Differences
|
|
|
|
### Known Differences
|
|
|
|
| Field | v3.0.49+ | v2.3.x |
|
|
|-------|----------|--------|
|
|
| ISP (Inlet Setpoint) | `"34.3 °C"` (string with unit) | May not exist |
|
|
| SSP (System Setpoint) | Present | May not exist |
|
|
| alarm.status | `true/false` | May only have `type` field |
|
|
| res (aux heater state) | Present | May not exist |
|
|
| sce | Present | May not exist |
|
|
|
|
### Checking Your Firmware Version
|
|
|
|
1. Access your heat pump URL in a browser
|
|
2. Look for the `sw.V` field in the response:
|
|
```json
|
|
{
|
|
"sw": { "V": "3.0.49" },
|
|
...
|
|
}
|
|
```
|
|
|
|
### Adapting for Different Firmware
|
|
|
|
If your firmware has different field names, you may need to modify `__init__.py`.
|
|
|
|
**Key mappings (line ~122-158):**
|
|
|
|
```python
|
|
"inlet_setpoint_temp": float(status.get("ISP", "0").split()[0]),
|
|
"system_setpoint_temp": status.get("SSP"),
|
|
"water_temp_t1": status.get("watert1"),
|
|
"water_temp_t2": status.get("watert2"),
|
|
"dhw_temp_t3": status.get("dhwt3"),
|
|
"outdoor_temp_t4": status.get("t4"),
|
|
"water_setpoint": status.get("watersetpoint"),
|
|
"dhw_setpoint": status.get("dhwsetpoint"),
|
|
"is_heating": status.get("heating", False),
|
|
"is_working": status.get("pwr", False),
|
|
"is_cooling": status.get("cooling", False),
|
|
"is_dhw": status.get("san", False),
|
|
"is_pump_active": status.get("pump", False),
|
|
"is_aux_heater": status.get("res", False),
|
|
"is_standby": status.get("standby", False),
|
|
```
|
|
|
|
**To find correct field names:**
|
|
1. Save your heat pump's JSON response to a file
|
|
2. Compare with the sample files in `jsons/` folder
|
|
3. Adjust the field names in `__init__.py` accordingly
|
|
|
|
## Temperature Reading Issues
|
|
|
|
### Incorrect Values
|
|
|
|
**Symptoms:** Temperature shows wrong values (e.g., 0 or very high numbers).
|
|
|
|
**Solutions:**
|
|
1. Check the JSON response format for temperature fields
|
|
2. Some fields may be strings with units (e.g., `"34.3 °C"`) that need parsing
|
|
3. Verify field names match your firmware version
|
|
|
|
### ISP Field Parsing Error
|
|
|
|
The ISP field often contains a string with unit: `"34.3 °C"`
|
|
|
|
The code parses this with:
|
|
```python
|
|
float(status.get("ISP", "0").split()[0])
|
|
```
|
|
|
|
If your firmware returns a different format, adjust accordingly.
|
|
|
|
## Setting Temperature Issues
|
|
|
|
### Set Temperature Not Working
|
|
|
|
**Symptoms:** Changing temperature in thermostat card doesn't affect heat pump.
|
|
|
|
**Solutions:**
|
|
1. Check Home Assistant logs for errors
|
|
2. Verify the SetParameter endpoint is correct
|
|
3. Test manually:
|
|
```bash
|
|
curl -X POST "http://YOUR_IP/installedplugin/com.innova.pdc/VERSION/server/index.php?Action=SetParameter" \
|
|
-d "Key=watersetpoint&Value=45&manual=forever"
|
|
```
|
|
|
|

|
|
*Check logs when setting temperature fails*
|
|
|
|
## Debug Logging
|
|
|
|
Enable debug logging for more information:
|
|
|
|
Add to `configuration.yaml`:
|
|
```yaml
|
|
logger:
|
|
default: info
|
|
logs:
|
|
custom_components.rdz_innova_heatpump: debug
|
|
```
|
|
|
|
Then restart Home Assistant and check logs.
|
|
|
|
## Sample JSON Files
|
|
|
|
The repository includes sample JSON responses for reference:
|
|
|
|
| File | Firmware | Description |
|
|
|------|----------|-------------|
|
|
| `jsons/og.json` | v3.0.49 | Full feature set |
|
|
| `jsons/bogdan.json` | v2.3.2 | Reduced features |
|
|
|
|
Compare your heat pump's response with these files to identify differences.
|
|
|
|
## Getting Help
|
|
|
|
### Gathering Information
|
|
|
|
When reporting issues, include:
|
|
1. Home Assistant version
|
|
2. Heat pump firmware version (from JSON `sw.V` field)
|
|
3. Full JSON response from your heat pump (sanitize IP if needed)
|
|
4. Relevant log entries
|
|
5. Steps to reproduce
|
|
|
|
### Sharing Your JSON
|
|
|
|
If you have a different firmware version, consider sharing your JSON response to help improve compatibility:
|
|
|
|
1. Save your JSON response
|
|
2. Remove any sensitive information
|
|
3. Submit as an issue or pull request
|
|
|
|
## FAQ
|
|
|
|
**Q: How often does the integration poll the heat pump?**
|
|
A: Default is every 3 seconds. Configurable during setup or in options.
|
|
|
|
**Q: Can I use this with other heat pump brands?**
|
|
A: This integration is designed for RDZ PDC heat pumps with Innova web interface. Other brands may have different APIs.
|
|
|
|
**Q: Does this work without internet?**
|
|
A: Yes, this is a local polling integration. No cloud services required.
|
|
|
|
**Q: Why are some fields missing in my version?**
|
|