Common Issues
Integration Not Appearing
Symptoms: After copying files and restarting, "Heat Pump Monitor" doesn't appear in the integrations list.
Solutions:
- Verify the folder structure is correct:
custom_components/ └── rdz_innova_heatpump/ ├── __init__.py ├── manifest.json └── ... other files - Check file permissions
- Perform a full restart (not just reload)
- Check Home Assistant logs for errors
Check Home Assistant logs for error messages
Connection Failed
Symptoms: "Failed to connect" error during setup.
Solutions:
- Verify the URL is accessible from your HA server:
curl http://YOUR_HEAT_PUMP_IP/installedplugin/com.innova.pdc/VERSION/server/index.php?Action=GetStatus - Check network connectivity between HA and heat pump
- Verify the URL format is correct
- Check if heat pump web interface is responding
Missing Sensors
Symptoms: Some sensors show "Unknown" or "Unavailable".
Solutions: This is often due to firmware version differences. Different versions have different JSON structures.
Some sensors may show unavailable due to firmware differences
Firmware Version Differences
Known Differences
| Field | v3.0.49+ | v2.3.x |
|---|---|---|
| ISP (Inlet Setpoint) | "34.3 °C" (string with unit) |
May not exist |
| SSP (System Setpoint) | Present | May not exist |
| alarm.status | true/false |
May only have type field |
| res (aux heater state) | Present | May not exist |
| sce | Present | May not exist |
Checking Your Firmware Version
- Access your heat pump URL in a browser
- Look for the
sw.Vfield in the response:{ "sw": { "V": "3.0.49" }, ... }
Adapting for Different Firmware
If your firmware has different field names, you may need to modify __init__.py.
Key mappings (line ~122-158):
"inlet_setpoint_temp": float(status.get("ISP", "0").split()[0]),
"system_setpoint_temp": status.get("SSP"),
"water_temp_t1": status.get("watert1"),
"water_temp_t2": status.get("watert2"),
"dhw_temp_t3": status.get("dhwt3"),
"outdoor_temp_t4": status.get("t4"),
"water_setpoint": status.get("watersetpoint"),
"dhw_setpoint": status.get("dhwsetpoint"),
"is_heating": status.get("heating", False),
"is_working": status.get("pwr", False),
"is_cooling": status.get("cooling", False),
"is_dhw": status.get("san", False),
"is_pump_active": status.get("pump", False),
"is_aux_heater": status.get("res", False),
"is_standby": status.get("standby", False),
To find correct field names:
- Save your heat pump's JSON response to a file
- Compare with the sample files in
jsons/folder - Adjust the field names in
__init__.pyaccordingly
Temperature Reading Issues
Incorrect Values
Symptoms: Temperature shows wrong values (e.g., 0 or very high numbers).
Solutions:
- Check the JSON response format for temperature fields
- Some fields may be strings with units (e.g.,
"34.3 °C") that need parsing - Verify field names match your firmware version
ISP Field Parsing Error
The ISP field often contains a string with unit: "34.3 °C"
The code parses this with:
float(status.get("ISP", "0").split()[0])
If your firmware returns a different format, adjust accordingly.
Setting Temperature Issues
Set Temperature Not Working
Symptoms: Changing temperature in thermostat card doesn't affect heat pump.
Solutions:
- Check Home Assistant logs for errors
- Verify the SetParameter endpoint is correct
- Test manually:
curl -X POST "http://YOUR_IP/installedplugin/com.innova.pdc/VERSION/server/index.php?Action=SetParameter" \ -d "Key=watersetpoint&Value=45&manual=forever"
Check logs when setting temperature fails
Debug Logging
Enable debug logging for more information:
Add to configuration.yaml:
logger:
default: info
logs:
custom_components.rdz_innova_heatpump: debug
Then restart Home Assistant and check logs.
Sample JSON Files
The repository includes sample JSON responses for reference:
| File | Firmware | Description |
|---|---|---|
jsons/og.json |
v3.0.49 | Full feature set |
jsons/bogdan.json |
v2.3.2 | Reduced features |
Compare your heat pump's response with these files to identify differences.
Getting Help
Gathering Information
When reporting issues, include:
- Home Assistant version
- Heat pump firmware version (from JSON
sw.Vfield) - Full JSON response from your heat pump (sanitize IP if needed)
- Relevant log entries
- Steps to reproduce
Sharing Your JSON
If you have a different firmware version, consider sharing your JSON response to help improve compatibility:
- Save your JSON response
- Remove any sensitive information
- Submit as an issue or pull request
FAQ
Q: How often does the integration poll the heat pump? A: Default is every 3 seconds. Configurable during setup or in options.
Q: Can I use this with other heat pump brands? A: This integration is designed for RDZ PDC heat pumps with Innova web interface. Other brands may have different APIs.
Q: Does this work without internet? A: Yes, this is a local polling integration. No cloud services required.
Q: Why are some fields missing in my version? A: Different firmware versions expose different data. Older versions may lack some sensors.