Preparing for public release
This commit is contained in:
@@ -0,0 +1,30 @@
|
||||
title: RDZ PDC Heat Pump Monitor
|
||||
description: Home Assistant custom integration for RDZ PDC heat pumps
|
||||
remote_theme: pages-themes/cayman@v0.2.0
|
||||
plugins:
|
||||
- jekyll-remote-theme
|
||||
|
||||
# Navigation
|
||||
header_pages:
|
||||
- index.md
|
||||
- installation.md
|
||||
- configuration.md
|
||||
- dashboard.md
|
||||
- troubleshooting.md
|
||||
- api.md
|
||||
|
||||
# Build settings
|
||||
markdown: kramdown
|
||||
highlighter: rouge
|
||||
|
||||
# GitHub repository info
|
||||
github:
|
||||
is_project_page: true
|
||||
repository_url: https://github.com/your-username/rdz_innova_heatpump
|
||||
|
||||
# Defaults
|
||||
defaults:
|
||||
- scope:
|
||||
path: ""
|
||||
values:
|
||||
layout: default
|
||||
+275
@@ -0,0 +1,275 @@
|
||||
---
|
||||
layout: default
|
||||
title: API Reference
|
||||
nav_order: 6
|
||||
---
|
||||
|
||||
# API Reference
|
||||
|
||||
## Heat Pump Web API
|
||||
|
||||
The integration communicates with the heat pump's embedded web server.
|
||||
|
||||
### Get Status
|
||||
|
||||
Retrieves current heat pump status and sensor readings.
|
||||
|
||||
**Endpoint:**
|
||||
```
|
||||
GET /installedplugin/com.innova.pdc/<VERSION>/server/index.php?Action=GetStatus
|
||||
```
|
||||
|
||||
**Response:**
|
||||
```json
|
||||
{
|
||||
"sw": { "V": "3.0.49" },
|
||||
"success": true,
|
||||
"model": "RDZ",
|
||||
"RESULT": {
|
||||
"TSLastUpdate": 1759138628,
|
||||
"info": {
|
||||
"datetime": "29/09/2025 12:37"
|
||||
},
|
||||
"status": {
|
||||
"ISP": "34.3 °C",
|
||||
"SSP": 47.0,
|
||||
"watert1": 32.1,
|
||||
"watert2": 32.0,
|
||||
"dhwt3": 46.8,
|
||||
"t4": 9.6,
|
||||
"watersetpoint": 43.0,
|
||||
"dhwsetpoint": 47.0,
|
||||
"heating": true,
|
||||
"cooling": false,
|
||||
"pwr": false,
|
||||
"san": false,
|
||||
"pump": true,
|
||||
"res": false,
|
||||
"standby": false,
|
||||
"sce": true,
|
||||
"alarm": {
|
||||
"status": false,
|
||||
"type": "",
|
||||
"label": ""
|
||||
},
|
||||
"worktime_pdc": 11614,
|
||||
"worktime_res": 593
|
||||
}
|
||||
}
|
||||
}
|
||||
```
|
||||
|
||||
### Status Fields
|
||||
|
||||
| Field | Type | Description |
|
||||
|-------|------|-------------|
|
||||
| `ISP` | string | Inlet Setpoint (e.g., "34.3 °C") |
|
||||
| `SSP` | float | System Setpoint |
|
||||
| `watert1` | float | Inflow water temperature |
|
||||
| `watert2` | float | Outflow water temperature |
|
||||
| `dhwt3` | float | Domestic hot water temperature |
|
||||
| `t4` | float | Outdoor temperature |
|
||||
| `watersetpoint` | float | Water temperature setpoint |
|
||||
| `dhwsetpoint` | float | DHW temperature setpoint |
|
||||
| `heating` | bool | Heating mode active |
|
||||
| `cooling` | bool | Cooling mode active |
|
||||
| `pwr` | bool | Compressor running |
|
||||
| `san` | bool | DHW mode active |
|
||||
| `pump` | bool | Circulation pump active |
|
||||
| `res` | bool | Auxiliary heater active |
|
||||
| `standby` | bool | Standby mode |
|
||||
| `sce` | bool | Smart Consumer Electronics |
|
||||
| `alarm.status` | bool | Alarm active |
|
||||
| `alarm.type` | string | Alarm type code |
|
||||
| `alarm.label` | string | Alarm description |
|
||||
| `worktime_pdc` | int | Compressor runtime (hours) |
|
||||
| `worktime_res` | int | Aux heater runtime (hours) |
|
||||
|
||||
### Set Parameter
|
||||
|
||||
Sets a heat pump parameter (temperature setpoint).
|
||||
|
||||
**Endpoint:**
|
||||
```
|
||||
POST /installedplugin/com.innova.pdc/<VERSION>/server/index.php?Action=SetParameter
|
||||
```
|
||||
|
||||
**Content-Type:** `application/x-www-form-urlencoded`
|
||||
|
||||
**Parameters:**
|
||||
|
||||
| Parameter | Type | Required | Description |
|
||||
|-----------|------|----------|-------------|
|
||||
| `Key` | string | Yes | Parameter name: `watersetpoint` or `dhwsetpoint` |
|
||||
| `Value` | string | Yes | Temperature value |
|
||||
| `manual` | string | Yes | Duration: `forever` or time-based |
|
||||
|
||||
**Example:**
|
||||
```bash
|
||||
curl -X POST "http://192.168.1.100/installedplugin/com.innova.pdc/2.0.10/server/index.php?Action=SetParameter" \
|
||||
-H "Content-Type: application/x-www-form-urlencoded" \
|
||||
-d "Key=watersetpoint&Value=45&manual=forever"
|
||||
```
|
||||
|
||||
**Response:** HTTP 200 on success
|
||||
|
||||
---
|
||||
|
||||
## Home Assistant Services
|
||||
|
||||
### rdz_innova_heatpump.set_water_setpoint
|
||||
|
||||
Manually set the heating water temperature setpoint.
|
||||
|
||||
**Service Data:**
|
||||
|
||||
| Attribute | Type | Required | Description |
|
||||
|-----------|------|----------|-------------|
|
||||
| `temperature` | float | Yes | Target temperature (35-60°C) |
|
||||
| `duration` | string | No | Duration: "forever" (default) or time-based |
|
||||
|
||||
**Example YAML:**
|
||||
```yaml
|
||||
service: rdz_innova_heatpump.set_water_setpoint
|
||||
data:
|
||||
temperature: 45
|
||||
duration: forever
|
||||
```
|
||||
|
||||
**Example Automation:**
|
||||
```yaml
|
||||
automation:
|
||||
- alias: "Set water temperature on schedule"
|
||||
trigger:
|
||||
- platform: time
|
||||
at: "06:00:00"
|
||||
action:
|
||||
- service: rdz_innova_heatpump.set_water_setpoint
|
||||
data:
|
||||
temperature: 45
|
||||
duration: forever
|
||||
```
|
||||
|
||||
---
|
||||
|
||||
## Entities
|
||||
|
||||
### Climate Entity
|
||||
|
||||
**Entity ID:** `climate.heat_pump_water_temperature`
|
||||
|
||||
**Attributes:**
|
||||
|
||||
| Attribute | Description |
|
||||
|-----------|-------------|
|
||||
| `current_temperature` | Current water temperature (T1) |
|
||||
| `temperature` | Target temperature setpoint |
|
||||
| `hvac_mode` | Current mode: `heat`, `cool`, `off` |
|
||||
| `hvac_action` | Current action: `heating`, `cooling`, `idle`, `off` |
|
||||
| `min_temp` | Minimum setpoint (35°C) |
|
||||
| `max_temp` | Maximum setpoint (60°C) |
|
||||
| `target_temp_step` | Temperature step (0.5°C) |
|
||||
|
||||
**Supported Features:**
|
||||
- `TARGET_TEMPERATURE`
|
||||
|
||||
**HVAC Modes:**
|
||||
- `heat` - Heating mode
|
||||
- `cool` - Cooling mode
|
||||
- `off` - Standby
|
||||
|
||||
### Water Heater Entity
|
||||
|
||||
**Entity ID:** `water_heater.heat_pump_dhw`
|
||||
|
||||
**Attributes:**
|
||||
|
||||
| Attribute | Description |
|
||||
|-----------|-------------|
|
||||
| `current_temperature` | Current DHW temperature (T3) |
|
||||
| `temperature` | Target DHW setpoint |
|
||||
| `operation_mode` | `on` when DHW active, `off` otherwise |
|
||||
| `min_temp` | Minimum setpoint (35°C) |
|
||||
| `max_temp` | Maximum setpoint (60°C) |
|
||||
|
||||
### Sensor Entities
|
||||
|
||||
| Entity ID | Unit | Description |
|
||||
|-----------|------|-------------|
|
||||
| `sensor.heat_pump_inlet_setpoint_temperature` | °C | ISP value |
|
||||
| `sensor.heat_pump_system_setpoint_temperature` | °C | SSP value |
|
||||
| `sensor.heat_pump_water_temperature_t1` | °C | Inflow temperature |
|
||||
| `sensor.heat_pump_outflow_temperature_t2` | °C | Outflow temperature |
|
||||
| `sensor.heat_pump_dhw_temperature_t3` | °C | DHW temperature |
|
||||
| `sensor.heat_pump_outdoor_temperature_t4` | °C | Outdoor temperature |
|
||||
| `sensor.heat_pump_water_setpoint` | °C | Water setpoint |
|
||||
| `sensor.heat_pump_dhw_setpoint` | °C | DHW setpoint |
|
||||
| `sensor.heat_pump_runtime` | h | Compressor hours |
|
||||
| `sensor.heat_pump_auxiliary_heater_runtime` | h | Aux heater hours |
|
||||
| `sensor.heat_pump_software_version` | - | Firmware version |
|
||||
|
||||
### Binary Sensor Entities
|
||||
|
||||
| Entity ID | Device Class | Description |
|
||||
|-----------|--------------|-------------|
|
||||
| `binary_sensor.heat_pump_heating` | heat | Heating mode |
|
||||
| `binary_sensor.heat_pump_cooling` | cold | Cooling mode |
|
||||
| `binary_sensor.heat_pump_working` | running | Compressor active |
|
||||
| `binary_sensor.heat_pump_dhw_mode` | running | DHW mode |
|
||||
| `binary_sensor.heat_pump_water_pump` | running | Pump active |
|
||||
| `binary_sensor.heat_pump_auxiliary_heater` | heat | Aux heater active |
|
||||
| `binary_sensor.heat_pump_standby` | power | Standby mode |
|
||||
| `binary_sensor.heat_pump_disabled_prod` | power | Production disabled |
|
||||
| `binary_sensor.heat_pump_sce` | power | SCE active |
|
||||
| `binary_sensor.heat_pump_alarm` | problem | Alarm active |
|
||||
|
||||
---
|
||||
|
||||
## Internal Data Structure
|
||||
|
||||
The coordinator maintains this internal data structure:
|
||||
|
||||
```python
|
||||
{
|
||||
"software_version": "3.0.49",
|
||||
"last_update": 1759138628,
|
||||
"datetime": "29/09/2025 12:37",
|
||||
|
||||
# Temperatures
|
||||
"inlet_setpoint_temp": 34.3,
|
||||
"system_setpoint_temp": 47.0,
|
||||
"water_temp_t1": 32.1,
|
||||
"water_temp_t2": 32.0,
|
||||
"dhw_temp_t3": 46.8,
|
||||
"outdoor_temp_t4": 9.6,
|
||||
"water_setpoint": 43.0,
|
||||
"dhw_setpoint": 47.0,
|
||||
"aux_heater": 0,
|
||||
|
||||
# States
|
||||
"is_heating": True,
|
||||
"is_cooling": False,
|
||||
"is_working": False,
|
||||
"is_dhw": False,
|
||||
"is_pump_active": True,
|
||||
"is_aux_heater": False,
|
||||
"is_standby": False,
|
||||
"disabled_prod": False,
|
||||
"sce": True,
|
||||
|
||||
# Runtimes
|
||||
"worktime_pdc": 11614,
|
||||
"worktime_res": 593,
|
||||
|
||||
# Alarms
|
||||
"has_alarm": False,
|
||||
"alarm_type": "",
|
||||
"alarm_label": ""
|
||||
}
|
||||
```
|
||||
|
||||
Access in custom code:
|
||||
```python
|
||||
coordinator = hass.data[DOMAIN][entry.entry_id]
|
||||
temp = coordinator.data.get("water_temp_t1")
|
||||
```
|
||||
@@ -0,0 +1,49 @@
|
||||
# Image Placeholders
|
||||
|
||||
Add screenshots to this folder. The documentation references the following images:
|
||||
|
||||
## Home Page
|
||||
- `dashboard-overview.png` - Main dashboard overview screenshot
|
||||
|
||||
## Installation Page
|
||||
- `file-structure.png` - File explorer showing correct directory structure
|
||||
- `restart-ha.png` - Home Assistant restart screen
|
||||
- `search-integration.png` - Integration search dialog
|
||||
- `add-integration.png` - Add integration confirmation
|
||||
- `device-overview.png` - Device page showing all entities
|
||||
|
||||
## Configuration Page
|
||||
- `devtools-network.png` - Browser DevTools Network tab showing API request
|
||||
- `json-response.png` - Example JSON response in browser
|
||||
- `config-url.png` - Configuration wizard URL input step
|
||||
- `config-interval.png` - Configuration wizard interval input step
|
||||
- `config-confirm.png` - Configuration confirmation screen
|
||||
- `reconfigure.png` - Integration options/reconfigure screen
|
||||
- `rename-entity.png` - Entity customization dialog
|
||||
|
||||
## Dashboard Page
|
||||
- `dashboard-full.png` - Complete dashboard view
|
||||
- `dashboard-import.png` - Raw configuration editor for importing
|
||||
- `dashboard-status-buttons.png` - Status button row close-up
|
||||
- `dashboard-thermostats.png` - Thermostat cards close-up
|
||||
- `dashboard-history.png` - History graph close-up
|
||||
- `dashboard-scheduler.png` - Scheduler card (if installed)
|
||||
- `dashboard-gauge.png` - Example gauge card
|
||||
- `dashboard-mobile.png` - Mobile view of dashboard
|
||||
|
||||
## Troubleshooting Page
|
||||
- `troubleshoot-logs.png` - Home Assistant logs showing errors
|
||||
- `troubleshoot-missing-sensors.png` - Entities showing unavailable
|
||||
- `troubleshoot-set-temp.png` - Logs when setting temperature
|
||||
|
||||
## Recommended Screenshot Dimensions
|
||||
- Full page screenshots: 1200x800 px
|
||||
- Close-up/detail shots: 600x400 px
|
||||
- Mobile screenshots: 375x667 px (iPhone size)
|
||||
|
||||
## Tips for Good Screenshots
|
||||
1. Use a clean Home Assistant installation or demo mode
|
||||
2. Hide personal information (IP addresses, names)
|
||||
3. Use consistent theme (light or dark)
|
||||
4. Crop to show relevant areas
|
||||
5. Add annotations if helpful (arrows, highlights)
|
||||
@@ -0,0 +1,124 @@
|
||||
---
|
||||
layout: default
|
||||
title: Configuration
|
||||
nav_order: 3
|
||||
---
|
||||
|
||||
# Configuration
|
||||
|
||||
## Finding Your Heat Pump URL
|
||||
|
||||
The integration requires the URL to your heat pump's status API. The format is typically:
|
||||
|
||||
```
|
||||
http://<HEAT_PUMP_IP>/installedplugin/com.innova.pdc/<VERSION>/server/index.php?Action=GetStatus
|
||||
```
|
||||
|
||||
### Method 1: Browser Developer Tools
|
||||
|
||||
1. Access your heat pump's web interface in a browser
|
||||
2. Open browser developer tools (F12)
|
||||
3. Navigate to the **Network** tab
|
||||
4. Refresh the page or navigate the heat pump interface
|
||||
5. Look for requests to `index.php?Action=GetStatus`
|
||||
6. Copy the full URL
|
||||
|
||||

|
||||
*Use browser developer tools to find the correct API URL*
|
||||
|
||||
### Method 2: Common URL Patterns
|
||||
|
||||
Try these common URL patterns (replace IP with your heat pump's IP):
|
||||
|
||||
```
|
||||
http://192.168.1.100/installedplugin/com.innova.pdc/2.0.10/server/index.php?Action=GetStatus
|
||||
http://192.168.1.100/installedplugin/com.innova.pdc/3.0.49/server/index.php?Action=GetStatus
|
||||
```
|
||||
|
||||
### Verify Your URL
|
||||
|
||||
Open the URL in a browser. You should see a JSON response like:
|
||||
|
||||
```json
|
||||
{
|
||||
"success": true,
|
||||
"sw": { "V": "3.0.49" },
|
||||
"RESULT": {
|
||||
"status": {
|
||||
"watert1": 32.1,
|
||||
"watert2": 32.0,
|
||||
"heating": true,
|
||||
...
|
||||
}
|
||||
}
|
||||
}
|
||||
```
|
||||
|
||||

|
||||
*Expected JSON response when accessing the URL*
|
||||
|
||||
## Configuration Wizard
|
||||
|
||||
### Step 1: Enter URL
|
||||
|
||||
When adding the integration, enter your heat pump URL:
|
||||
|
||||

|
||||
*Enter the heat pump status URL*
|
||||
|
||||
### Step 2: Set Update Interval
|
||||
|
||||
Optionally configure the update interval (default: 3 seconds):
|
||||
|
||||
| Setting | Description | Recommended |
|
||||
|---------|-------------|-------------|
|
||||
| 1-2 seconds | Very frequent updates | High network load |
|
||||
| 3 seconds | Default, good balance | Recommended |
|
||||
| 5-10 seconds | Less frequent | Low network load |
|
||||
|
||||

|
||||
*Configure the polling interval*
|
||||
|
||||
### Step 3: Confirm Configuration
|
||||
|
||||
Review and confirm your settings:
|
||||
|
||||

|
||||
*Review configuration before completing setup*
|
||||
|
||||
## Configuration Options
|
||||
|
||||
After initial setup, you can modify options:
|
||||
|
||||
1. Go to **Settings** > **Devices & Services**
|
||||
2. Find "Heat Pump Monitor"
|
||||
3. Click **Configure**
|
||||
|
||||

|
||||
*Access configuration options after setup*
|
||||
|
||||
## Entity Customization
|
||||
|
||||
After setup, you may want to customize entities:
|
||||
|
||||
### Rename Entities
|
||||
|
||||
1. Go to **Settings** > **Devices & Services**
|
||||
2. Click on the Heat Pump device
|
||||
3. Click on an entity
|
||||
4. Change the name as desired
|
||||
|
||||

|
||||
*Customize entity names*
|
||||
|
||||
### Hide Unused Entities
|
||||
|
||||
If some sensors don't apply to your setup:
|
||||
|
||||
1. Click on the entity
|
||||
2. Toggle "Enable" off
|
||||
|
||||
## Next Steps
|
||||
|
||||
- [Set up the dashboard](dashboard.md)
|
||||
- [Troubleshoot issues](troubleshooting.md)
|
||||
@@ -0,0 +1,187 @@
|
||||
---
|
||||
layout: default
|
||||
title: Dashboard
|
||||
nav_order: 4
|
||||
---
|
||||
|
||||
# Dashboard Setup
|
||||
|
||||
A pre-configured dashboard is included with the integration to help you get started quickly.
|
||||
|
||||
## Dashboard Overview
|
||||
|
||||

|
||||
*Complete dashboard view with all components*
|
||||
|
||||
The dashboard includes:
|
||||
- Status indicator buttons
|
||||
- Thermostat cards for temperature control
|
||||
- History graphs for monitoring
|
||||
- Scheduler integration (optional)
|
||||
|
||||
## Installing the Dashboard
|
||||
|
||||
### Method 1: Import YAML
|
||||
|
||||
1. Go to **Settings** > **Dashboards**
|
||||
2. Click **+ Add Dashboard**
|
||||
3. Choose "New dashboard from scratch"
|
||||
4. Give it a name (e.g., "Heat Pump")
|
||||
5. Open the dashboard and click the three dots menu
|
||||
6. Select **Edit Dashboard**
|
||||
7. Click the three dots again and select **Raw configuration editor**
|
||||
8. Paste the contents of `dashboards/dash.yaml`
|
||||
9. Click **Save**
|
||||
|
||||

|
||||
*Import dashboard using raw configuration editor*
|
||||
|
||||
### Method 2: Add Cards Manually
|
||||
|
||||
You can also add individual cards to an existing dashboard.
|
||||
|
||||
## Dashboard Components
|
||||
|
||||
### Status Buttons
|
||||
|
||||

|
||||
*Status indicator buttons*
|
||||
|
||||
The top row shows quick status indicators:
|
||||
|
||||
| Button | Entity | Description |
|
||||
|--------|--------|-------------|
|
||||
| Alarm | `binary_sensor.heat_pump_alarm` | Shows alarm status |
|
||||
| Heating | `binary_sensor.heat_pump_heating` | Heating mode active |
|
||||
| Cooling | `binary_sensor.heat_pump_cooling` | Cooling mode active |
|
||||
| SCE | `binary_sensor.heat_pump_sce` | Smart Consumer Electronics |
|
||||
| Standby | `binary_sensor.heat_pump_standby` | Standby mode |
|
||||
|
||||
### Thermostat Cards
|
||||
|
||||

|
||||
*Thermostat cards for temperature control*
|
||||
|
||||
Two thermostat cards provide temperature control:
|
||||
|
||||
#### Water Temperature Thermostat
|
||||
- Entity: `climate.heat_pump_water_temperature`
|
||||
- Controls heating/cooling water setpoint
|
||||
- Shows current water temperature
|
||||
|
||||
#### DHW (Boiler) Thermostat
|
||||
- Entity: `water_heater.heat_pump_dhw` or `climate.boiler_temperature`
|
||||
- Controls domestic hot water setpoint
|
||||
- Shows current DHW temperature
|
||||
|
||||
### History Graph
|
||||
|
||||

|
||||
*24-hour history graph showing all sensors*
|
||||
|
||||
The history graph tracks:
|
||||
- All temperature sensors (T1, T2, T3, T4, setpoints)
|
||||
- Binary status sensors (heating, cooling, pump, DHW)
|
||||
- Runtime statistics
|
||||
|
||||
Configuration:
|
||||
```yaml
|
||||
type: history-graph
|
||||
hours_to_show: 24
|
||||
entities:
|
||||
- entity: sensor.heat_pump_water_temperature_t1
|
||||
- entity: sensor.heat_pump_dhw_temperature_t3
|
||||
- entity: sensor.heat_pump_outdoor_temperature_t4
|
||||
- entity: binary_sensor.heat_pump_heating
|
||||
- entity: binary_sensor.heat_pump_working
|
||||
# ... more entities
|
||||
```
|
||||
|
||||
### Scheduler Card (Optional)
|
||||
|
||||

|
||||
*Scheduler card for automation*
|
||||
|
||||
The scheduler requires the [scheduler-card](https://github.com/nielsfaber/scheduler-card) custom component.
|
||||
|
||||
Install via HACS:
|
||||
1. Open HACS
|
||||
2. Search for "scheduler-card"
|
||||
3. Install and restart
|
||||
|
||||
## Customizing the Dashboard
|
||||
|
||||
### Changing Time Range
|
||||
|
||||
Edit the history graph `hours_to_show` value:
|
||||
|
||||
```yaml
|
||||
type: history-graph
|
||||
hours_to_show: 48 # Change from 24 to 48 hours
|
||||
```
|
||||
|
||||
### Adding More Sensors
|
||||
|
||||
Add entities to the history graph:
|
||||
|
||||
```yaml
|
||||
entities:
|
||||
- entity: sensor.heat_pump_water_temperature_t1
|
||||
- entity: sensor.your_additional_sensor # Add new sensors
|
||||
```
|
||||
|
||||
### Changing Layout
|
||||
|
||||
Adjust grid columns for different screen sizes:
|
||||
|
||||
```yaml
|
||||
grid_options:
|
||||
columns: 12 # Full width
|
||||
rows: 4
|
||||
```
|
||||
|
||||
## Mobile View
|
||||
|
||||

|
||||
*Dashboard optimized for mobile view*
|
||||
|
||||
The dashboard is responsive and works on mobile devices. For better mobile experience, consider:
|
||||
- Using the sections layout
|
||||
- Reducing the number of history graph entities
|
||||
- Using compact card styles
|
||||
|
||||
## Example Cards
|
||||
|
||||
### Simple Temperature Display
|
||||
|
||||
```yaml
|
||||
type: entities
|
||||
entities:
|
||||
- entity: sensor.heat_pump_water_temperature_t1
|
||||
name: Inflow Temperature
|
||||
- entity: sensor.heat_pump_water_temperature_t2
|
||||
name: Outflow Temperature
|
||||
- entity: sensor.heat_pump_outdoor_temperature_t4
|
||||
name: Outdoor Temperature
|
||||
```
|
||||
|
||||
### Gauge Card
|
||||
|
||||
```yaml
|
||||
type: gauge
|
||||
entity: sensor.heat_pump_water_temperature_t1
|
||||
min: 20
|
||||
max: 60
|
||||
severity:
|
||||
green: 35
|
||||
yellow: 45
|
||||
red: 55
|
||||
```
|
||||
|
||||

|
||||
*Temperature gauge card example*
|
||||
|
||||
## Next Steps
|
||||
|
||||
- [Troubleshoot issues](troubleshooting.md)
|
||||
- [API Reference](api.md)
|
||||
@@ -0,0 +1,74 @@
|
||||
---
|
||||
layout: default
|
||||
title: Home
|
||||
nav_order: 1
|
||||
---
|
||||
|
||||
# RDZ PDC Heat Pump Monitor
|
||||
|
||||
A custom Home Assistant integration for monitoring and controlling RDZ PDC heat pumps via their embedded web interface.
|
||||
|
||||

|
||||
*Dashboard overview showing heat pump status and controls*
|
||||
|
||||
## Features
|
||||
|
||||
- **Climate Control** - Thermostat entity for controlling heating/cooling water temperature
|
||||
- **Water Heater Control** - Dedicated entity for domestic hot water (DHW) temperature control
|
||||
- **Comprehensive Monitoring** - 12+ sensors for temperatures, setpoints, and runtime statistics
|
||||
- **Status Indicators** - 10 binary sensors for operational states
|
||||
- **Local Polling** - Direct communication with heat pump, no cloud dependency
|
||||
- **Dashboard Included** - Pre-configured Lovelace dashboard YAML
|
||||
|
||||
## Supported Data Points
|
||||
|
||||
### Temperature Sensors
|
||||
|
||||
| Sensor | Description |
|
||||
|--------|-------------|
|
||||
| Inlet Setpoint (ISP) | Smart heating setpoint temperature |
|
||||
| System Setpoint (SSP) | System setpoint temperature |
|
||||
| Water T1 | Inflow/supply water temperature |
|
||||
| Water T2 | Outflow/return water temperature |
|
||||
| DHW T3 | Domestic hot water temperature |
|
||||
| Outdoor T4 | External/outdoor temperature |
|
||||
| Water Setpoint | Target heating water temperature |
|
||||
| DHW Setpoint | Target domestic hot water temperature |
|
||||
|
||||
### Status Sensors
|
||||
|
||||
| Sensor | Description |
|
||||
|--------|-------------|
|
||||
| Heating | Heat pump is in heating mode |
|
||||
| Cooling | Heat pump is in cooling mode |
|
||||
| Working | Compressor is running |
|
||||
| DHW Mode | Domestic hot water heating active |
|
||||
| Water Pump | Circulation pump is active |
|
||||
| Auxiliary Heater | Backup electric heater running |
|
||||
| Standby | System in standby mode |
|
||||
| Alarm | System alarm active |
|
||||
|
||||
### Runtime Statistics
|
||||
|
||||
| Sensor | Description |
|
||||
|--------|-------------|
|
||||
| Runtime (PDC) | Total compressor operating hours |
|
||||
| Auxiliary Heater Runtime | Total backup heater operating hours |
|
||||
|
||||
## Quick Links
|
||||
|
||||
- [Installation Guide](installation.md)
|
||||
- [Configuration](configuration.md)
|
||||
- [Dashboard Setup](dashboard.md)
|
||||
- [Troubleshooting](troubleshooting.md)
|
||||
- [API Reference](api.md)
|
||||
|
||||
## Requirements
|
||||
|
||||
- Home Assistant 2023.1 or newer
|
||||
- RDZ PDC heat pump with web interface
|
||||
- Network access to heat pump from Home Assistant
|
||||
|
||||
## License
|
||||
|
||||
This project is provided as-is for personal use with RDZ PDC heat pumps.
|
||||
@@ -0,0 +1,82 @@
|
||||
---
|
||||
layout: default
|
||||
title: Installation
|
||||
nav_order: 2
|
||||
---
|
||||
|
||||
# Installation
|
||||
|
||||
## Step 1: Download the Integration
|
||||
|
||||
Download or clone this repository to get the integration files.
|
||||
|
||||
```bash
|
||||
git clone https://github.com/your-username/rdz_innova_heatpump.git
|
||||
```
|
||||
|
||||
## Step 2: Copy Integration Files
|
||||
|
||||
Copy the `custom_components/rdz_innova_heatpump` folder to your Home Assistant `custom_components` directory.
|
||||
|
||||
```
|
||||
<config_directory>/
|
||||
└── custom_components/
|
||||
└── rdz_innova_heatpump/
|
||||
├── __init__.py
|
||||
├── climate.py
|
||||
├── sensor.py
|
||||
├── binary_sensor.py
|
||||
├── water_heater.py
|
||||
├── config_flow.py
|
||||
├── manifest.json
|
||||
└── translations/
|
||||
└── en.json
|
||||
```
|
||||
|
||||

|
||||
*Expected file structure after installation*
|
||||
|
||||
## Step 3: Restart Home Assistant
|
||||
|
||||
After copying the files, restart Home Assistant completely. This is required for Home Assistant to detect the new integration.
|
||||
|
||||

|
||||
*Restart Home Assistant from Settings > System*
|
||||
|
||||
## Step 4: Add Integration
|
||||
|
||||
1. Go to **Settings** > **Devices & Services**
|
||||
2. Click **+ Add Integration** button
|
||||
3. Search for "RDZ" or "Heat Pump Monitor"
|
||||
|
||||

|
||||
*Search for the integration in the Add Integration dialog*
|
||||
|
||||
4. Select "Heat Pump Monitor" from the results
|
||||
5. Follow the configuration wizard (see [Configuration](configuration.md))
|
||||
|
||||

|
||||
*The integration should appear in search results*
|
||||
|
||||
## Step 5: Verify Installation
|
||||
|
||||
After configuration, you should see:
|
||||
- A new device "Heat Pump" in your devices list
|
||||
- Multiple entities (sensors, binary sensors, climate, water heater)
|
||||
|
||||

|
||||
*Device overview showing all entities*
|
||||
|
||||
## Next Steps
|
||||
|
||||
- [Configure the integration](configuration.md)
|
||||
- [Set up the dashboard](dashboard.md)
|
||||
|
||||
## Troubleshooting Installation
|
||||
|
||||
If the integration doesn't appear:
|
||||
|
||||
1. Verify files are in the correct directory
|
||||
2. Check Home Assistant logs for errors
|
||||
3. Ensure you restarted Home Assistant completely (not just reload)
|
||||
4. See [Troubleshooting](troubleshooting.md) for more help
|
||||
@@ -0,0 +1,202 @@
|
||||
---
|
||||
layout: default
|
||||
title: Troubleshooting
|
||||
nav_order: 5
|
||||
---
|
||||
|
||||
# Troubleshooting
|
||||
|
||||
## Common Issues
|
||||
|
||||
### Integration Not Appearing
|
||||
|
||||
**Symptoms:** After copying files and restarting, "Heat Pump Monitor" doesn't appear in the integrations list.
|
||||
|
||||
**Solutions:**
|
||||
1. Verify the folder structure is correct:
|
||||
```
|
||||
custom_components/
|
||||
└── rdz_innova_heatpump/
|
||||
├── __init__.py
|
||||
├── manifest.json
|
||||
└── ... other files
|
||||
```
|
||||
2. Check file permissions
|
||||
3. Perform a full restart (not just reload)
|
||||
4. Check Home Assistant logs for errors
|
||||
|
||||

|
||||
*Check Home Assistant logs for error messages*
|
||||
|
||||
### Connection Failed
|
||||
|
||||
**Symptoms:** "Failed to connect" error during setup.
|
||||
|
||||
**Solutions:**
|
||||
1. Verify the URL is accessible from your HA server:
|
||||
```bash
|
||||
curl http://YOUR_HEAT_PUMP_IP/installedplugin/com.innova.pdc/VERSION/server/index.php?Action=GetStatus
|
||||
```
|
||||
2. Check network connectivity between HA and heat pump
|
||||
3. Verify the URL format is correct
|
||||
4. Check if heat pump web interface is responding
|
||||
|
||||
### Missing Sensors
|
||||
|
||||
**Symptoms:** Some sensors show "Unknown" or "Unavailable".
|
||||
|
||||
**Solutions:**
|
||||
This is often due to firmware version differences. Different versions have different JSON structures.
|
||||
|
||||

|
||||
*Some sensors may show unavailable due to firmware differences*
|
||||
|
||||
## Firmware Version Differences
|
||||
|
||||
### Known Differences
|
||||
|
||||
| Field | v3.0.49+ | v2.3.x |
|
||||
|-------|----------|--------|
|
||||
| ISP (Inlet Setpoint) | `"34.3 °C"` (string with unit) | May not exist |
|
||||
| SSP (System Setpoint) | Present | May not exist |
|
||||
| alarm.status | `true/false` | May only have `type` field |
|
||||
| res (aux heater state) | Present | May not exist |
|
||||
| sce | Present | May not exist |
|
||||
|
||||
### Checking Your Firmware Version
|
||||
|
||||
1. Access your heat pump URL in a browser
|
||||
2. Look for the `sw.V` field in the response:
|
||||
```json
|
||||
{
|
||||
"sw": { "V": "3.0.49" },
|
||||
...
|
||||
}
|
||||
```
|
||||
|
||||
### Adapting for Different Firmware
|
||||
|
||||
If your firmware has different field names, you may need to modify `__init__.py`.
|
||||
|
||||
**Key mappings (line ~122-158):**
|
||||
|
||||
```python
|
||||
"inlet_setpoint_temp": float(status.get("ISP", "0").split()[0]),
|
||||
"system_setpoint_temp": status.get("SSP"),
|
||||
"water_temp_t1": status.get("watert1"),
|
||||
"water_temp_t2": status.get("watert2"),
|
||||
"dhw_temp_t3": status.get("dhwt3"),
|
||||
"outdoor_temp_t4": status.get("t4"),
|
||||
"water_setpoint": status.get("watersetpoint"),
|
||||
"dhw_setpoint": status.get("dhwsetpoint"),
|
||||
"is_heating": status.get("heating", False),
|
||||
"is_working": status.get("pwr", False),
|
||||
"is_cooling": status.get("cooling", False),
|
||||
"is_dhw": status.get("san", False),
|
||||
"is_pump_active": status.get("pump", False),
|
||||
"is_aux_heater": status.get("res", False),
|
||||
"is_standby": status.get("standby", False),
|
||||
```
|
||||
|
||||
**To find correct field names:**
|
||||
1. Save your heat pump's JSON response to a file
|
||||
2. Compare with the sample files in `jsons/` folder
|
||||
3. Adjust the field names in `__init__.py` accordingly
|
||||
|
||||
## Temperature Reading Issues
|
||||
|
||||
### Incorrect Values
|
||||
|
||||
**Symptoms:** Temperature shows wrong values (e.g., 0 or very high numbers).
|
||||
|
||||
**Solutions:**
|
||||
1. Check the JSON response format for temperature fields
|
||||
2. Some fields may be strings with units (e.g., `"34.3 °C"`) that need parsing
|
||||
3. Verify field names match your firmware version
|
||||
|
||||
### ISP Field Parsing Error
|
||||
|
||||
The ISP field often contains a string with unit: `"34.3 °C"`
|
||||
|
||||
The code parses this with:
|
||||
```python
|
||||
float(status.get("ISP", "0").split()[0])
|
||||
```
|
||||
|
||||
If your firmware returns a different format, adjust accordingly.
|
||||
|
||||
## Setting Temperature Issues
|
||||
|
||||
### Set Temperature Not Working
|
||||
|
||||
**Symptoms:** Changing temperature in thermostat card doesn't affect heat pump.
|
||||
|
||||
**Solutions:**
|
||||
1. Check Home Assistant logs for errors
|
||||
2. Verify the SetParameter endpoint is correct
|
||||
3. Test manually:
|
||||
```bash
|
||||
curl -X POST "http://YOUR_IP/installedplugin/com.innova.pdc/VERSION/server/index.php?Action=SetParameter" \
|
||||
-d "Key=watersetpoint&Value=45&manual=forever"
|
||||
```
|
||||
|
||||

|
||||
*Check logs when setting temperature fails*
|
||||
|
||||
## Debug Logging
|
||||
|
||||
Enable debug logging for more information:
|
||||
|
||||
Add to `configuration.yaml`:
|
||||
```yaml
|
||||
logger:
|
||||
default: info
|
||||
logs:
|
||||
custom_components.rdz_innova_heatpump: debug
|
||||
```
|
||||
|
||||
Then restart Home Assistant and check logs.
|
||||
|
||||
## Sample JSON Files
|
||||
|
||||
The repository includes sample JSON responses for reference:
|
||||
|
||||
| File | Firmware | Description |
|
||||
|------|----------|-------------|
|
||||
| `jsons/og.json` | v3.0.49 | Full feature set |
|
||||
| `jsons/bogdan.json` | v2.3.2 | Reduced features |
|
||||
|
||||
Compare your heat pump's response with these files to identify differences.
|
||||
|
||||
## Getting Help
|
||||
|
||||
### Gathering Information
|
||||
|
||||
When reporting issues, include:
|
||||
1. Home Assistant version
|
||||
2. Heat pump firmware version (from JSON `sw.V` field)
|
||||
3. Full JSON response from your heat pump (sanitize IP if needed)
|
||||
4. Relevant log entries
|
||||
5. Steps to reproduce
|
||||
|
||||
### Sharing Your JSON
|
||||
|
||||
If you have a different firmware version, consider sharing your JSON response to help improve compatibility:
|
||||
|
||||
1. Save your JSON response
|
||||
2. Remove any sensitive information
|
||||
3. Submit as an issue or pull request
|
||||
|
||||
## FAQ
|
||||
|
||||
**Q: How often does the integration poll the heat pump?**
|
||||
A: Default is every 3 seconds. Configurable during setup or in options.
|
||||
|
||||
**Q: Can I use this with other heat pump brands?**
|
||||
A: This integration is designed for RDZ PDC heat pumps with Innova web interface. Other brands may have different APIs.
|
||||
|
||||
**Q: Does this work without internet?**
|
||||
A: Yes, this is a local polling integration. No cloud services required.
|
||||
|
||||
**Q: Why are some fields missing in my version?**
|
||||
A: Different firmware versions expose different data. Older versions may lack some sensors.
|
||||
Reference in New Issue