Boiler Auxiliary Heater Control

A Home Assistant custom integration for intelligently controlling an auxiliary electric heating element inside a DHW (Domestic Hot Water) boiler. Designed for systems where a heat pump is the primary heat source and an electric resistance heater is the secondary element.

The integration maximises PV self-consumption by diverting surplus solar energy to the boiler, while also supporting on-demand bath boost heating and fully configurable temperature presets.


Features

  • PV Excess Diversion — monitors up to 3 CT clamps (single-phase or 3-phase) and activates the heater only when there is enough surplus export, using configurable start/stop delays to avoid rapid cycling
  • Bath Boost — one-tap hot water on demand; activates the heater and optionally runs the DHW circulation pump for a configurable duration, then automatically restores the previous state
  • 5 Temperature Presets — Normal, Eco, Boost, Sleep, Away, each with individually adjustable target temperatures
  • All-Modes Boost — optional mode that lets the aux heater top up the boiler whenever the thermostat demands heat, regardless of PV availability
  • Safety Interlocks — hard cut-off temperature, HP aux heater interlock (disables aux heater while the heat pump's own electric element is running), and safe defaults for unavailable sensors
  • Energy Tracking — separate kWh counters for total, PV-sourced, and grid-sourced energy, compatible with HA's Energy Dashboard
  • Decision Transparency — a Decision Reason sensor tells you exactly why the heater is on or off at any moment
  • Persistent State — all settings and an active bath boost survive HA restarts
  • Ready-to-Use Dashboard — an importable Lovelace dashboard is included

Requirements

  • Home Assistant 2024.1.0 or newer
  • A temperature sensor measuring the boiler water temperature (device class: temperature)
  • A switch entity controlling the heater relay
  • One or more power sensors measuring grid import/export at each phase (device class: power, negative = export)

Optional:

  • A binary sensor indicating whether the heat pump's own auxiliary heater is active (for interlock)
  • A switch entity for a DHW circulation pump (enables the bath boost button)
  • A scheduler entity for the pump (its schedule is restored after bath boost)

Installation

  1. Open HACS in Home Assistant
  2. Go to Integrations → click the three-dot menu → Custom repositories
  3. Add this repository URL and select category Integration
  4. Search for Boiler Auxiliary Heater Control and install
  5. Restart Home Assistant

Manual

  1. Copy the custom_components/boiler_aux_heater_3phase folder into your HA config/custom_components/ directory
  2. Restart Home Assistant

Configuration

Navigate to Settings → Devices & Services → Add Integration and search for Boiler Auxiliary Heater Control.

The setup wizard has three steps:

Step 1 — Core Hardware

Field Description
Boiler temperature sensor Sensor measuring the DHW tank temperature (must have device class temperature)
Heater relay switch The switch entity that controls the heating element

Step 2 — Solar Monitoring

Field Description
Number of phases 1 Phase or 3 Phases
Phase 1 CT power sensor Grid power sensor for phase 1 (negative = exporting)
Phase 2 CT power sensor Phase 2 sensor (3-phase only, optional)
Phase 3 CT power sensor Phase 3 sensor (3-phase only, optional)

Important: the CT sensors must report negative values for export and positive values for import. This is the convention used by most inverter integrations (Fronius, SolarEdge, Huawei, etc.).

Step 3 — Optional Devices

Field Description
HP aux heater sensor Binary sensor that is on when the heat pump's own electric element is active. If provided, the aux heater is disabled while this sensor is on. If the sensor becomes unavailable, the aux heater is disabled as a safety measure.
Circulation pump switch Switch controlling a DHW circulation pump. When provided, the Bath Boost button entities are created.
Pump schedule entity A scheduler entity whose schedule is re-applied after bath boost finishes.

After initial setup, all entity references can be changed via Configure on the integration card.


Entities

Climate

Entity Description
climate.boiler_auxiliary_heater Main thermostat. Set HVAC mode (heat/off) and choose a preset.

Presets: Normal · Eco · Boost · Sleep · Away

Selecting the Boost preset starts the bath boost timer. Selecting any other preset while boost is active cancels the boost.


Switches (Configuration)

Entity Default Description
switch…allow_aux_heater_usage ON Master enable. Turn off to disable the aux heater entirely.
switch…pv_excess_mode ON Enable PV excess diversion.
switch…boost_in_all_modes OFF Allow the heater to run whenever the thermostat demands heat, regardless of PV. Uses the larger all-modes hysteresis to avoid short cycling.
switch…manual_override OFF Force the relay ON, bypassing all logic. For testing or emergencies only.

Numbers (Configuration)

Temperatures

Entity Default Range Description
number…cut_off_temperature 60 °C 40–85 Hard safety limit. Heater is always off above this temperature.
number…temperature_hysteresis 4 °C 1–15 How far below the target temperature heating must be demanded before activating. Also used as PV shadow thermostat cold tolerance.
number…pv_target_temperature 55 °C 40–70 Target temperature for PV excess mode. Max is automatically capped at cut_off_temp - 1.
number…normal_preset_temperature 44 °C 30–65 Target for Normal preset.
number…eco_preset_temperature 40 °C 30–60 Target for Eco preset.
number…boost_preset_temperature 50 °C 40–70 Target for Boost preset.
number…sleep_preset_temperature 38 °C 25–55 Target for Sleep preset.
number…away_preset_temperature 35 °C 20–50 Target for Away preset.

PV Excess Settings

Entity Default Range Description
number…heater_power_rating 4500 W 1500–9000 Rated wattage of the heating element. Used for PV surplus threshold and energy calculations.
number…pv_excess_buffer 100 W 0–1000 Additional margin required above heater power before PV mode activates. Prevents marginal activation.
number…pv_excess_start_delay 60 s 1–300 How long PV surplus must be sustained before activating. Prevents cloud transients from triggering the heater.
number…pv_excess_stop_delay 60 s 1–300 How long PV deficit must be sustained before deactivating. Allows short shading events without turning off.

Bath Boost & All-Modes Settings

Entity Default Range Description
number…bath_boost_duration 30 min 5–120 How long bath boost runs.
number…all_modes_boost_hysteresis 10 °C 3–20 Temperature must be this far below target for all-modes boost to activate. Larger value → heater activates less often.
number…boost_recovery_offset 3 °C 0–15 All-modes boost turns off when temperature reaches target - boost_recovery_offset.

Binary Sensors (Status)

Entity Description
binary_sensor…heater_decision on = heater relay should be on right now.
binary_sensor…pv_power_sufficient on = current PV export is enough to run the heater.
binary_sensor…running_on_pv on = heater is running and powered by PV surplus.
binary_sensor…running_on_grid on = heater is running on grid power (bath boost or all-modes boost).
binary_sensor…bath_boost_active on = bath boost timer is running.

Sensors (Status)

Entity Description
sensor…heater_power Current total power consumption of the heater (W).
sensor…heater_pv_power Current power drawn from PV surplus (W).
sensor…heater_grid_power Current power drawn from the grid (W).
sensor…heater_energy Total energy consumed (kWh) — suitable for HA Energy Dashboard.
sensor…heater_pv_energy Energy consumed from PV (kWh).
sensor…heater_grid_energy Energy consumed from grid (kWh).
sensor…bath_boost_remaining Seconds remaining in the current bath boost (0 when inactive).
sensor…decision_reason Human-readable text explaining the current heater decision, e.g. "PV excess heating" or "OFF: HP aux heater active".
sensor…pv_excess_state PV state machine state: idle, waiting_to_start, active, or waiting_to_stop.

Buttons (optional — only if circulation pump is configured)

Entity Description
button…start_bath_boost Start the bath boost timer immediately.
button…cancel_bath_boost Cancel an active bath boost and restore previous state.

Services

Both services are always available, regardless of whether a circulation pump is configured.

boiler_aux_heater_3phase.start_bath_boost

Starts the bath boost. Saves the current climate preset, activates the Boost preset, starts the countdown timer, and (if configured) turns on the circulation pump.

service: boiler_aux_heater_3phase.start_bath_boost

boiler_aux_heater_3phase.stop_bath_boost

Cancels an active bath boost, restores the previous preset, and (if configured) turns off the circulation pump and re-applies the pump schedule.

service: boiler_aux_heater_3phase.stop_bath_boost

Events

When a bath boost expires naturally (timer runs out), the integration fires:

event: boiler_aux_heater_3phase_boost_finished
data:
  duration_minutes: 30
  pre_boost_preset: "Normal"
  restored_preset: "Normal"

You can use this event in automations to notify occupants or take further action.


How the PV Excess Logic Works

For each active CT phase:
  Turn-on threshold:  CT_value < -(heater_power / phases + pv_buffer / phases)
  Stay-on threshold:  CT_value <= 0   (any export at all)

State machine:
  IDLE  ──[all phases meet turn-on threshold]──►  WAITING_TO_START
  WAITING_TO_START  ──[pv_start_delay elapsed]──►  ACTIVE
  WAITING_TO_START  ──[PV drops]──►  IDLE
  ACTIVE  ──[any phase stops exporting]──►  WAITING_TO_STOP
  WAITING_TO_STOP  ──[pv_stop_delay elapsed]──►  IDLE
  WAITING_TO_STOP  ──[PV recovers]──►  ACTIVE

While in ACTIVE or WAITING_TO_STOP, the PV shadow thermostat checks whether the boiler temperature is below pv_target_temp. This prevents unnecessarily overheating the tank on very sunny days.


Dashboard

A ready-to-use Lovelace dashboard is included in custom_components/boiler_aux_heater_3phase/dashboard.yaml.

To import it:

  1. Go to Settings → Dashboards → Add Dashboard
  2. Or use the Raw Configuration Editor in an existing dashboard and paste the YAML

The dashboard includes sections for:

  • Thermostat control with preset dropdown
  • Bath boost controls and timer
  • Mode switches
  • Preset temperature configuration
  • Safety and heater settings
  • PV excess settings
  • Live status (decision, PV state, power & energy)

Automation Examples

Notify when bath boost finishes

automation:
  - alias: "Notify bath boost done"
    trigger:
      - platform: event
        event_type: boiler_aux_heater_3phase_boost_finished
    action:
      - service: notify.mobile_app_my_phone
        data:
          message: "Hot water ready! Tank heated for {{ trigger.event.data.duration_minutes }} minutes."

Switch to Away preset when leaving home

automation:
  - alias: "Boiler away mode"
    trigger:
      - platform: state
        entity_id: person.resident
        to: not_home
    action:
      - service: climate.set_preset_mode
        target:
          entity_id: climate.boiler_auxiliary_heater
        data:
          preset_mode: Away

Start bath boost on a schedule

automation:
  - alias: "Morning bath boost"
    trigger:
      - platform: time
        at: "07:00:00"
    condition:
      - condition: state
        entity_id: binary_sensor.workday_sensor
        state: "on"
    action:
      - service: boiler_aux_heater_3phase.start_bath_boost

Troubleshooting

Heater never activates in PV mode

  • Check sensor…pv_excess_state — if it stays idle, the CT sensors may not be reporting negative values when exporting. Confirm the sign convention of your inverter integration.
  • Check that switch…pv_excess_mode is on and switch…allow_aux_heater_usage is on.
  • Check sensor…decision_reason for the exact reason the heater is off.
  • Increase pv_excess_buffer to 0 temporarily to rule out threshold issues.

HP aux heater interlock keeps the heater off

  • If the HP aux heater binary sensor reads unavailable, the integration disables the aux heater as a safety measure. Check the sensor entity or remove it from the configuration if not needed.

Bath boost buttons are missing

  • The bath boost buttons are only created when a circulation pump switch is configured. Go to Configure on the integration card to add one. The start_bath_boost and stop_bath_boost services are always available regardless.

Energy counters reset after restart

  • Energy sensors use RestoreEntity to persist their values. If values are lost, check that the HA recorder is running and that the entities are not excluded from recording.

PV mode activates but heater stays off

  • Check sensor…decision_reason. Common causes: boiler temperature above cut_off_temperature, HVAC mode set to off, or allow_aux_heater_usage switch is off.

License