This repository has been archived on 2026-04-06. You can view files and clone it. You cannot open issues or pull requests or push a commit.
Files

222 lines
7.1 KiB
YAML

views:
- title: DHW
type: sections
max_columns: 4
icon: ''
subview: false
sections:
- type: grid
cards:
- type: heading
heading: Monitoring
heading_style: title
- type: custom:scheduler-card
include:
- climate.boiler_temperature
- input_boolean.dhw_allow_aux_heater_in_all_modes
- input_boolean.dhw_allow_aux_heater_usage
- timer.bath_time
exclude: []
grid_options:
columns: 24
rows: auto
- type: thermostat
entity: climate.boiler_temperature
features:
- type: climate-preset-modes
style: dropdown
show_current_as_primary: true
- type: history-graph
entities:
- entity: binary_sensor.heat_pump_auxiliary_heater
- entity: switch.boiler_heater_relay_switch_0
- entity: binary_sensor.heat_pump_dhw_mode
title: Boiler History
grid_options:
columns: 36
rows: auto
- type: history-graph
entities:
- entity: input_boolean.dhw_allow_aux_heater_usage
- entity: input_boolean.dhw_allow_aux_heater_in_all_modes
- entity: input_boolean.dhw_aux_heater_manual_override
- entity: input_boolean.dhw_use_excess_pv_for_aux_heater
- entity: binary_sensor.dhw_pv_power_enough_for_aux_heater
- entity: binary_sensor.dhw_use_boiler_aux_heater
title: Boiler History
grid_options:
columns: 36
rows: auto
- type: history-graph
entities:
- entity: sensor.boiler_temp
- entity: sensor.heat_pump_inflow_temperature_t1
- entity: sensor.heat_pump_dhw_setpoint
title: Boiler History
grid_options:
columns: 36
rows: auto
- type: grid
cards: []
column_span: 4
- type: grid
cards:
- type: heading
heading: Settings
heading_style: title
- type: tile
entity: switch.acm_pump_switch
features_position: bottom
vertical: true
show_entity_picture: false
tap_action:
action: toggle
column_span: 4
- type: grid
cards:
- type: heading
heading_style: title
badges: []
heading: Boiler Aux Heater Settings
icon: mdi:heating-coil
- features:
- type: toggle
type: tile
entity: input_boolean.dhw_aux_heater_manual_override
features_position: bottom
vertical: false
state_content: last_changed
grid_options:
columns: full
- features:
- type: toggle
type: tile
entity: input_boolean.dhw_allow_aux_heater_usage
features_position: bottom
vertical: false
state_content: last_updated
grid_options:
columns: full
- features: &ref_1
- type: toggle
type: tile
entity: input_boolean.dhw_allow_aux_heater_in_all_modes
features_position: bottom
vertical: false
state_content: last_changed
grid_options: &ref_0
columns: full
rows: 2
- type: tile
grid_options: *ref_0
entity: input_boolean.dhw_bath_boost
state_content: last_changed
vertical: false
features: *ref_1
features_position: bottom
- features:
- type: numeric-input
style: buttons
type: tile
entity: input_number.dhw_aux_heater_cut_off_temperature_threshold
features_position: bottom
vertical: false
state_content: last_changed
grid_options:
columns: full
- features:
- type: numeric-input
style: buttons
type: tile
entity: input_number.dhw_aux_heater_temperature_threshold
features_position: bottom
vertical: false
state_content: last_changed
grid_options:
columns: full
- type: grid
cards:
- type: heading
heading: Alerts
heading_style: title
icon: mdi:alert
- features:
- type: numeric-input
style: buttons
type: tile
entity: input_number.dhw_hi_temperature_alert_threshold
features_position: bottom
vertical: false
hide_state: true
grid_options:
columns: full
- type: grid
cards:
- type: heading
heading: PV Excess Usage Settings
heading_style: title
icon: mdi:solar-power-variant
- features:
- type: toggle
type: tile
entity: input_boolean.dhw_use_excess_pv_for_aux_heater
features_position: bottom
vertical: false
state_content: last_changed
grid_options:
columns: full
rows: 2
- features:
- type: numeric-input
style: buttons
type: tile
entity: input_number.dhw_aux_heater_power
features_position: bottom
vertical: false
state_content: last_changed
grid_options:
columns: full
rows: 2
- features:
- style: buttons
type: numeric-input
type: tile
entity: input_number.dhw_pv_excess_usage_start_delay
features_position: bottom
vertical: false
state_content: last_changed
grid_options:
columns: full
rows: 2
- features:
- type: numeric-input
style: buttons
type: tile
entity: input_number.dhw_pv_excess_usage_stop_delay
features_position: bottom
vertical: false
state_content: last_changed
grid_options:
columns: full
rows: 2
- features:
- type: numeric-input
style: buttons
type: tile
entity: input_number.dhw_pv_excess_usage_buffer
features_position: bottom
vertical: false
hide_state: false
show_entity_picture: false
grid_options:
columns: full
rows: 2
header:
card:
type: markdown
content: |-
# Domestic Hot Water Configuration
Configure the domestic hot water settings and rules here
text_only: true
path: adminDHW
cards: []