"""Constants for RDZ HMI Control integration."""
|
|
|
|
DOMAIN = "rdz_hmi_control"
|
|
|
|
# Modbus connection defaults
|
|
DEFAULT_PORT = 8000
|
|
DEFAULT_SCAN_INTERVAL = 30
|
|
|
|
# Modbus register addresses
|
|
REGISTER_TEMP_START = 2700
|
|
REGISTER_TEMP_COUNT = 64
|
|
|
|
REGISTER_WINTER_SETPOINT_START = 300
|
|
REGISTER_WINTER_SETPOINT_COUNT = 64
|
|
|
|
REGISTER_SUMMER_SETPOINT_START = 364
|
|
REGISTER_SUMMER_SETPOINT_COUNT = 64
|
|
|
|
# Coil addresses
|
|
COIL_SEASON = 2 # 0 = winter, 1 = summer
|
|
|
|
# Activity bitmask registers (4 registers, 16 bits each = 64 zones)
|
|
REGISTER_ACTIVITY_START = 2892
|
|
REGISTER_ACTIVITY_COUNT = 4
|
|
|
|
# Zone request bitmask registers (4 registers each, 16 bits = 64 zones)
|
|
REGISTER_HUMIDITY_REQUEST_START = 2896
|
|
REGISTER_HUMIDITY_REQUEST_COUNT = 4
|
|
|
|
REGISTER_VENTILATION_REQUEST_START = 2900
|
|
REGISTER_VENTILATION_REQUEST_COUNT = 4
|
|
|
|
REGISTER_RENEWAL_REQUEST_START = 2904
|
|
REGISTER_RENEWAL_REQUEST_COUNT = 4
|
|
|
|
REGISTER_INTEGRATION_REQUEST_START = 2908
|
|
REGISTER_INTEGRATION_REQUEST_COUNT = 4
|
|
|
|
REGISTER_DEHUMIDIFICATION_PUMP_START = 2912
|
|
REGISTER_DEHUMIDIFICATION_PUMP_COUNT = 4
|
|
|
|
# Humidity registers
|
|
REGISTER_HUMIDITY_START = 7701
|
|
REGISTER_HUMIDITY_COUNT = 64
|
|
|
|
# Summer dehumidification setpoint registers
|
|
REGISTER_DEHUMIDIFICATION_SETPOINT_START = 428
|
|
REGISTER_DEHUMIDIFICATION_SETPOINT_COUNT = 64
|
|
|
|
# Dew point registers
|
|
REGISTER_DEW_POINT_START = 2828
|
|
REGISTER_DEW_POINT_COUNT = 64
|
|
|
|
# Calculated setpoint registers (program-calculated target temperatures)
|
|
REGISTER_CALCULATED_SETPOINT_START = 2764
|
|
REGISTER_CALCULATED_SETPOINT_COUNT = 64
|
|
|
|
# Zone mode registers
|
|
REGISTER_ZONE_MODE_START = 5301
|
|
REGISTER_ZONE_MODE_COUNT = 64
|
|
|
|
# Zone mode values
|
|
ZONE_MODE_OFF = 0
|
|
ZONE_MODE_MAN = 1
|
|
ZONE_MODE_PGM = 2
|
|
ZONE_MODE_PGM_MAN = 3
|
|
|
|
ZONE_MODE_OPTIONS = {
|
|
ZONE_MODE_OFF: "Off",
|
|
ZONE_MODE_MAN: "Man",
|
|
ZONE_MODE_PGM: "Pgm",
|
|
ZONE_MODE_PGM_MAN: "Pgm/Man",
|
|
}
|
|
|
|
# Config keys
|
|
CONF_HOST = "host"
|
|
CONF_PORT = "port"
|
|
CONF_ZONES = "zones"
|
|
|
|
# Zone config keys
|
|
CONF_ZONE_ID = "zone_id"
|
|
CONF_ZONE_NAME = "name"
|
|
CONF_ZONE_TYPE = "type"
|
|
CONF_LINKED_VIRTUAL_ZONE = "linked_virtual_zone"
|
|
CONF_HVAC_MODE = "hvac_mode"
|
|
|
|
# Thermostat types
|
|
THERMOSTAT_TYPE_REAL = "real"
|
|
THERMOSTAT_TYPE_VIRTUAL = "virtual"
|
|
THERMOSTAT_TYPE_UNCONFIGURED = "unconfigured"
|
|
|
|
# Data keys in coordinator
|
|
DATA_TEMPERATURES = "temperatures"
|
|
DATA_WINTER_SETPOINTS = "winter_setpoints"
|
|
DATA_SUMMER_SETPOINTS = "summer_setpoints"
|
|
DATA_SEASON = "season" # True = summer, False = winter
|
|
DATA_ZONE_ACTIVITY = "zone_activity" # dict[int, bool] - zone_id -> is_active
|
|
DATA_HUMIDITY_REQUEST = "humidity_request"
|
|
DATA_VENTILATION_REQUEST = "ventilation_request"
|
|
DATA_RENEWAL_REQUEST = "renewal_request"
|
|
DATA_INTEGRATION_REQUEST = "integration_request"
|
|
DATA_DEHUMIDIFICATION_PUMP = "dehumidification_pump"
|
|
DATA_HUMIDITY = "humidity"
|
|
DATA_DEHUMIDIFICATION_SETPOINTS = "dehumidification_setpoints"
|
|
DATA_DEW_POINTS = "dew_points"
|
|
DATA_ZONE_MODES = "zone_modes"
|
|
|
|
# Temperature scale factor (Modbus returns values * 10)
|
|
TEMP_SCALE_FACTOR = 10.0
|
|
|
|
# Min/Max temperature limits
|
|
MIN_TEMP = 5.0
|
|
MAX_TEMP = 35.0
|
|
TEMP_STEP = 0.5
|
|
|
|
# Humidity limits
|
|
MIN_HUMIDITY = 30
|
|
MAX_HUMIDITY = 90
|
|
|
|
# Outside temperature register
|
|
REGISTER_OUTSIDE_TEMP = 2600
|
|
|
|
# Time settings registers (Day, Month, Year, Hour, Minute)
|
|
REGISTER_TIME_DAY = 5009
|
|
REGISTER_TIME_MONTH = 5010
|
|
REGISTER_TIME_YEAR = 5011
|
|
REGISTER_TIME_HOUR = 5012
|
|
REGISTER_TIME_MINUTE = 5013
|
|
|
|
# System activation coils
|
|
COIL_SYSTEM_ACTIVATION_START = 100
|
|
COIL_SYSTEM_ACTIVATION_COUNT = 8
|
|
|
|
# Water temperature registers
|
|
REGISTER_DELIVERY_WATER_TEMP_START = 2650
|
|
REGISTER_DELIVERY_WATER_TEMP_COUNT = 8
|
|
REGISTER_CALCULATED_WATER_TEMP_START = 2658
|
|
REGISTER_CALCULATED_WATER_TEMP_COUNT = 8
|
|
|
|
# Pump active bitmask register
|
|
REGISTER_PUMP_ACTIVE = 7615
|
|
|
|
# Ventilation mode registers (LSB = on/off)
|
|
REGISTER_VENTILATION_MODE_DEHUMIDIFICATION = 8201
|
|
REGISTER_VENTILATION_MODE_VENTILATION = 8202
|
|
REGISTER_VENTILATION_MODE_RENEWAL = 8203
|
|
REGISTER_VENTILATION_MODE_INTEGRATION = 8204
|
|
|
|
# Data keys for new features
|
|
DATA_OUTSIDE_TEMP = "outside_temperature"
|
|
DATA_TIME_SETTINGS = "time_settings"
|
|
DATA_SYSTEM_ACTIVATION = "system_activation"
|
|
DATA_DELIVERY_WATER_TEMPS = "delivery_water_temps"
|
|
DATA_CALCULATED_WATER_TEMPS = "calculated_water_temps"
|
|
DATA_PUMP_ACTIVE = "pump_active"
|
|
DATA_CALCULATED_SETPOINTS = "calculated_setpoints"
|
|
DATA_VENTILATION_MODE_DEHUMIDIFICATION = "ventilation_mode_dehumidification"
|
|
DATA_VENTILATION_MODE_VENTILATION = "ventilation_mode_ventilation"
|
|
DATA_VENTILATION_MODE_RENEWAL = "ventilation_mode_renewal"
|
|
DATA_VENTILATION_MODE_INTEGRATION = "ventilation_mode_integration"
|