# RS485 to Ethernet Module - Software Configuration Guide ## Overview This guide covers the essential software configuration of the 2-CH RS485 to Ethernet adapter. Configuration is done via web browser - no software installation required. ## What You Need to Configure **Only two things are critical:** 1. **IP Address** - Match your network 2. **Baud Rate** - Set to 19200 (or match your devices) All other settings can remain at their defaults. ## Quick Start ### Default Module Settings - **Channel 1**: `192.168.1.200` - **Channel 2**: `192.168.1.201` - **Default Port**: `4196` - **No password required** (first login) ### Step 1: Access the Web Interface 1. Temporarily set your computer's IP to `192.168.1.100` (same network as module) 2. Open web browser and go to: - Channel 1: `http://192.168.1.200` - Channel 2: `http://192.168.1.201` 3. Click "Login" (leave password blank on first access) ### Step 2: Change IP Address **Network Settings section:** - **Device IP**: Change to your network (example: `192.168.11.200`) - **Subnet Mask**: Usually `255.255.255.0` - **Gateway**: Your router IP (example: `192.168.11.1`) - Leave other settings as default > **Important**: Each channel needs a unique IP! Use sequential IPs like `.200` and `.201` ### Step 3: Set Baud Rate **Serial Settings section:** - **Baud Rate**: Set to `19200` - Leave other serial settings as default (8 databits, None parity, 1 stopbit) ### Step 4: Save and Repeat 1. Click **"Submit Modification"** 2. Access the module at its new IP address 3. Repeat Steps 1-4 for Channel 2 with a different IP ## Configuration Summary ### Essential Settings to Change | Setting | Channel 1 | Channel 2 | |---------|-----------|-----------| | **Device IP** | `192.168.x.200` | `192.168.x.201` | | **Baud Rate** | `19200` | `19200` | ### Other Settings (Keep Defaults) The web interface shows additional settings that can remain at defaults: - Work Mode: TCP Server - Device Port: 4196 - IP mode: Static - Databits: 8 - Parity: None - Stopbits: 1 - Flow control: None - Advanced Settings: Keep defaults - Multi-Host Settings: Keep defaults ## LED Indicators After configuration, check the module's LEDs: | LED | Expected Status | |-----|----------------| | **PWR** | Solid (power on) | | **NET** | Blinking (network connected) | | **LINK1/2** | On (RS485 connection) | | **ACT1/2** | Blinking (data transmission) | ## Troubleshooting ### Can't Access Web Interface 1. Verify your computer is on `192.168.1.x` network 2. Check Ethernet cable is connected 3. Ensure module is powered (PWR LED lit) 4. **Reset if needed**: Hold RESET button for 5 seconds (reverts to `192.168.1.254`) ### Can't Access After Changing IP 1. Update your computer's IP to match the new network 2. Verify gateway and subnet mask are correct 3. If lost, reset module and start over ### No RS485 Communication 1. Verify baud rate is set to `19200` 2. Check RS485 wiring: A to A (T+), B to B (T-) 3. Ensure RS485 devices are powered ## Configuration Checklist - [ ] Accessed Channel 1 web interface (`192.168.1.200`) - [ ] Changed Channel 1 IP to match my network - [ ] Set Channel 1 baud rate to `19200` - [ ] Saved and verified Channel 1 settings - [ ] Accessed Channel 2 web interface (`192.168.1.201`) - [ ] Changed Channel 2 IP to match my network (unique from Channel 1) - [ ] Set Channel 2 baud rate to `19200` - [ ] Saved and verified Channel 2 settings - [ ] Verified LED indicators are working ## Example Configuration Based on network `192.168.11.x`: **Channel 1** (`http://192.168.11.200`): ``` Device IP: 192.168.11.200 Baud Rate: 19200 Subnet Mask: 255.255.255.0 Gateway: 192.168.11.1 ``` **Channel 2** (`http://192.168.11.201`): ``` Device IP: 192.168.11.201 Baud Rate: 19200 Subnet Mask: 255.255.255.0 Gateway: 192.168.11.1 ``` --- **For Additional Help**: - **Waveshare Wiki**: https://www.waveshare.com/wiki/2-CH_RS485_TO_ETH_(B) - **Support**: Contact us for configuration assistance **Last Updated**: January 2026