Working version

This commit is contained in:
Constantin Pascal
2025-12-28 10:58:51 +02:00
commit bc976e33b3
10 changed files with 1542 additions and 0 deletions
+143
View File
@@ -0,0 +1,143 @@
"""Climate platform for Modbus RTU Monitor."""
from __future__ import annotations
from typing import Any
from homeassistant.components.climate import (
ClimateEntity,
ClimateEntityFeature,
HVACMode,
)
from homeassistant.const import ATTR_TEMPERATURE, UnitOfTemperature
from homeassistant.core import HomeAssistant, callback
from homeassistant.exceptions import HomeAssistantError
from homeassistant.helpers.device_registry import DeviceInfo
from homeassistant.helpers.entity_platform import AddEntitiesCallback
from homeassistant.helpers.update_coordinator import CoordinatorEntity
from . import ModbusRTUMonitorConfigEntry
from .const import DOMAIN, MANUFACTURER, MODEL
from .coordinator import ModbusRTUMonitorCoordinator
async def async_setup_entry(
hass: HomeAssistant,
entry: ModbusRTUMonitorConfigEntry,
async_add_entities: AddEntitiesCallback,
) -> None:
"""Set up climate entities from a config entry."""
coordinator = entry.runtime_data
# Track which slaves have climate entities
added_slaves: set[int] = set()
@callback
def _async_add_climate_entities() -> None:
"""Add climate entities for newly discovered slaves."""
if coordinator.data is None:
return
current_slaves = set(coordinator.data.keys())
new_slaves = current_slaves - added_slaves
if new_slaves:
async_add_entities(
ModbusRTUMonitorClimate(coordinator, slave_id)
for slave_id in new_slaves
)
added_slaves.update(new_slaves)
# Subscribe to coordinator updates
entry.async_on_unload(
coordinator.async_add_listener(_async_add_climate_entities)
)
# Add entities for already discovered slaves
_async_add_climate_entities()
class ModbusRTUMonitorClimate(
CoordinatorEntity[ModbusRTUMonitorCoordinator], ClimateEntity
):
"""Climate entity for Modbus RTU temperature monitor."""
_attr_has_entity_name = True
_attr_name = None # Device name will be used
_attr_temperature_unit = UnitOfTemperature.CELSIUS
_attr_hvac_modes = [HVACMode.HEAT] # Always on, no off mode
_attr_supported_features = ClimateEntityFeature.TARGET_TEMPERATURE
def __init__(
self,
coordinator: ModbusRTUMonitorCoordinator,
slave_id: int,
) -> None:
"""Initialize climate entity."""
super().__init__(coordinator)
self._slave_id = slave_id
self._attr_unique_id = (
f"{coordinator.config_entry.entry_id}_{slave_id}_climate"
)
# Device info (groups climate + humidity sensor)
self._attr_device_info = DeviceInfo(
identifiers={(DOMAIN, f"{coordinator.config_entry.entry_id}_{slave_id}")},
name=f"Modbus Slave {slave_id}",
manufacturer=MANUFACTURER,
model=MODEL,
)
# Target temperature storage (not available from passive monitoring)
self._attr_target_temperature = 20.0 # Default
@property
def available(self) -> bool:
"""Return if entity is available."""
if self._slave_id not in self.coordinator.data:
return False
return self.coordinator.data[self._slave_id].available
@property
def current_temperature(self) -> float | None:
"""Return current temperature from passive monitoring."""
if self._slave_id not in self.coordinator.data:
return None
return self.coordinator.data[self._slave_id].temperature
@property
def hvac_mode(self) -> HVACMode:
"""Return current HVAC mode."""
# Always HEAT mode (no on/off control as per requirements)
return HVACMode.HEAT
async def async_set_temperature(self, **kwargs: Any) -> None:
"""Set new target temperature and write to device."""
if (temperature := kwargs.get(ATTR_TEMPERATURE)) is None:
return
# Update local target temperature
self._attr_target_temperature = temperature
# Write to device via hub
try:
await self.coordinator.hub.async_write_setpoint(
self._slave_id,
temperature,
)
except Exception as ex:
raise HomeAssistantError(
f"Failed to set temperature for slave {self._slave_id}"
) from ex
# Update state
self.async_write_ha_state()
async def async_set_hvac_mode(self, hvac_mode: HVACMode) -> None:
"""Set HVAC mode."""
# No on/off control - only HEAT mode supported
if hvac_mode != HVACMode.HEAT:
raise HomeAssistantError(
f"HVAC mode {hvac_mode} not supported. Only HEAT mode is available."
)