Working version with heating reading
This commit is contained in:
+41
-4
@@ -7,6 +7,7 @@ from typing import Any
|
||||
from homeassistant.components.climate import (
|
||||
ClimateEntity,
|
||||
ClimateEntityFeature,
|
||||
HVACAction,
|
||||
HVACMode,
|
||||
)
|
||||
from homeassistant.const import ATTR_TEMPERATURE, UnitOfTemperature
|
||||
@@ -17,7 +18,7 @@ from homeassistant.helpers.entity_platform import AddEntitiesCallback
|
||||
from homeassistant.helpers.update_coordinator import CoordinatorEntity
|
||||
|
||||
from . import ModbusRTUMonitorConfigEntry
|
||||
from .const import DOMAIN, MANUFACTURER, MODEL
|
||||
from .const import DOMAIN, HEATING_STATUS_REGISTER, MANUFACTURER, MODEL, SETPOINT_REGISTER
|
||||
from .coordinator import ModbusRTUMonitorCoordinator
|
||||
|
||||
|
||||
@@ -89,8 +90,8 @@ class ModbusRTUMonitorClimate(
|
||||
model=MODEL,
|
||||
)
|
||||
|
||||
# Target temperature storage (not available from passive monitoring)
|
||||
self._attr_target_temperature = 20.0 # Default
|
||||
# Target temperature cache (synced from register 144 when available)
|
||||
self._attr_target_temperature = 20.0 # Default fallback
|
||||
|
||||
@property
|
||||
def available(self) -> bool:
|
||||
@@ -106,11 +107,47 @@ class ModbusRTUMonitorClimate(
|
||||
return None
|
||||
return self.coordinator.data[self._slave_id].temperature
|
||||
|
||||
@property
|
||||
def target_temperature(self) -> float | None:
|
||||
"""Return target temperature from device register or local cache."""
|
||||
if self._slave_id not in self.coordinator.data:
|
||||
return self._attr_target_temperature
|
||||
|
||||
slave_data = self.coordinator.data[self._slave_id]
|
||||
|
||||
# Try to read from register 144 (setpoint register)
|
||||
if slave_data.registers and SETPOINT_REGISTER in slave_data.registers:
|
||||
# Scale register value (divide by 10) to get temperature in °C
|
||||
setpoint_raw = slave_data.registers[SETPOINT_REGISTER]
|
||||
# Update local cache to stay in sync with device
|
||||
self._attr_target_temperature = setpoint_raw / 10.0
|
||||
return self._attr_target_temperature
|
||||
|
||||
# Fall back to local cache if register not yet read
|
||||
return self._attr_target_temperature
|
||||
|
||||
@property
|
||||
def hvac_mode(self) -> HVACMode:
|
||||
"""Return current HVAC mode."""
|
||||
# Always HEAT mode (no on/off control as per requirements)
|
||||
return HVACMode.HEAT
|
||||
return HVACMode.AUTO
|
||||
|
||||
@property
|
||||
def hvac_action(self) -> HVACAction | None:
|
||||
"""Return current HVAC action based on heating status register."""
|
||||
if self._slave_id not in self.coordinator.data:
|
||||
return None
|
||||
|
||||
slave_data = self.coordinator.data[self._slave_id]
|
||||
|
||||
# Read heating status from register 213
|
||||
if slave_data.registers and HEATING_STATUS_REGISTER in slave_data.registers:
|
||||
heating_status = slave_data.registers[HEATING_STATUS_REGISTER]
|
||||
# Return HEATING if register value is 1, otherwise IDLE
|
||||
return HVACAction.HEATING if heating_status == 1 else HVACAction.IDLE
|
||||
|
||||
# If register not available, return None (unknown state)
|
||||
return None
|
||||
|
||||
async def async_set_temperature(self, **kwargs: Any) -> None:
|
||||