Custom integration for heat pump monitoring via web interface.
|
|
Place this code in custom_components/heat_pump_monitor/__init__.py
|
|
"""
|
|
from homeassistant.config_entries import ConfigEntry
|
|
from homeassistant.core import HomeAssistant
|
|
|
|
async def async_setup(hass: HomeAssistant, config: dict) -> bool:
|
|
"""Set up the Heat Pump Monitor component."""
|
|
hass.data.setdefault(DOMAIN, {})
|
|
return True
|
|
|
|
async def async_unload_entry(hass: HomeAssistant, entry: ConfigEntry) -> bool:
|
|
"""Unload a config entry."""
|
|
unload_ok = await hass.config_entries.async_unload_platforms(entry, PLATFORMS)
|
|
if unload_ok:
|
|
hass.data[DOMAIN].pop(entry.entry_id)
|
|
return unload_ok
|
|
import asyncio
|
|
import logging
|
|
import aiohttp
|
|
from datetime import timedelta
|
|
from homeassistant.core import HomeAssistant
|
|
from homeassistant.config_entries import ConfigEntry
|
|
from homeassistant.const import (
|
|
CONF_URL,
|
|
CONF_SCAN_INTERVAL,
|
|
UnitOfTemperature,
|
|
TIME_HOURS,
|
|
)
|
|
from homeassistant.helpers.update_coordinator import (
|
|
CoordinatorEntity,
|
|
DataUpdateCoordinator,
|
|
UpdateFailed,
|
|
)
|
|
|
|
_LOGGER = logging.getLogger(__name__)
|
|
DOMAIN = "ha_rdz_pdc_config"
|
|
DEFAULT_SCAN_INTERVAL = 3
|
|
|
|
PLATFORMS = ["sensor", "binary_sensor"]
|
|
|
|
async def async_setup_entry(hass: HomeAssistant, entry: ConfigEntry) -> bool:
|
|
"""Set up heat pump monitor from a config entry."""
|
|
url = entry.data[CONF_URL]
|
|
scan_interval = entry.options.get(CONF_SCAN_INTERVAL, DEFAULT_SCAN_INTERVAL)
|
|
|
|
coordinator = HeatPumpDataCoordinator(
|
|
hass,
|
|
_LOGGER,
|
|
url=url,
|
|
update_interval=timedelta(seconds=scan_interval),
|
|
)
|
|
|
|
await coordinator.async_config_entry_first_refresh()
|
|
|
|
hass.data.setdefault(DOMAIN, {})
|
|
hass.data[DOMAIN][entry.entry_id] = coordinator
|
|
|
|
await hass.config_entries.async_forward_entry_setups(entry, PLATFORMS)
|
|
return True
|
|
|
|
class HeatPumpDataCoordinator(DataUpdateCoordinator):
|
|
"""Class to manage fetching heat pump data."""
|
|
|
|
def __init__(
|
|
self,
|
|
hass: HomeAssistant,
|
|
logger: logging.Logger,
|
|
url: str,
|
|
update_interval: timedelta,
|
|
) -> None:
|
|
"""Initialize."""
|
|
super().__init__(
|
|
hass,
|
|
logger,
|
|
name=DOMAIN,
|
|
update_interval=update_interval,
|
|
)
|
|
self.url = url
|
|
|
|
async def _async_update_data(self):
|
|
"""Fetch data from heat pump."""
|
|
try:
|
|
async with aiohttp.ClientSession() as session:
|
|
async with session.get(self.url) as response:
|
|
if response.status != 200:
|
|
raise UpdateFailed(f"Error fetching data: {response.status}")
|
|
data = await response.json()
|
|
|
|
if not data.get("success", False):
|
|
raise UpdateFailed("Heat pump returned unsuccessful response")
|
|
|
|
status = data.get("RESULT", {}).get("status", {})
|
|
return {
|
|
"software_version": data.get("sw", {}).get("V"),
|
|
"last_update": data.get("RESULT", {}).get("TSLastUpdate"),
|
|
"datetime": data.get("RESULT", {}).get("info", {}).get("datetime"),
|
|
# Temperature readings
|
|
# heating smart setpoint?
|
|
"inlet_setpoint_temp": float(status.get("ISP", "0").split()[0]),
|
|
# sanitary setpoint?
|
|
"system_setpoint_temp": status.get("SSP"),
|
|
"water_temp_t1": status.get("watert1"),
|
|
"water_temp_t2": status.get("watert2"),
|
|
"dhw_temp_t3": status.get("dhwt3"),
|
|
"outdoor_temp_t4": status.get("t4"),
|
|
# Setpoints
|
|
# heating water normal setpoint
|
|
"water_setpoint": status.get("watersetpoint"),
|
|
"dhw_setpoint": status.get("dhwsetpoint"),
|
|
# Operation states
|
|
"is_heating": status.get("heating", False),
|
|
"is_working": status.get("pwr", False),
|
|
"is_cooling": status.get("cooling", False),
|
|
"is_dhw": status.get("san", False),
|
|
"is_pump_active": status.get("pump", False),
|
|
"is_aux_heater" : status.get("res",False),
|
|
"aux_heater": status.get("auxheater", 0),
|
|
"is_standby": status.get("standby", False),
|
|
"disabled_prod": status.get("disableProd",False),
|
|
"sce": status.get("sce",False),
|
|
# Operation times
|
|
"worktime_pdc": status.get("worktime_pdc", 0),
|
|
"worktime_res": status.get("worktime_res", 0),
|
|
# Alarm status
|
|
"has_alarm": status.get("alarm", {}).get("status", False),
|
|
"alarm_type": status.get("alarm", {}).get("type", ""),
|
|
"alarm_label": status.get("alarm", {}).get("label", ""),
|
|
}
|
|
except aiohttp.ClientError as err:
|
|
raise UpdateFailed(f"Error communicating with heat pump: {err}") |