Preparing for public release
This commit is contained in:
+275
@@ -0,0 +1,275 @@
|
||||
---
|
||||
layout: default
|
||||
title: API Reference
|
||||
nav_order: 6
|
||||
---
|
||||
|
||||
# API Reference
|
||||
|
||||
## Heat Pump Web API
|
||||
|
||||
The integration communicates with the heat pump's embedded web server.
|
||||
|
||||
### Get Status
|
||||
|
||||
Retrieves current heat pump status and sensor readings.
|
||||
|
||||
**Endpoint:**
|
||||
```
|
||||
GET /installedplugin/com.innova.pdc/<VERSION>/server/index.php?Action=GetStatus
|
||||
```
|
||||
|
||||
**Response:**
|
||||
```json
|
||||
{
|
||||
"sw": { "V": "3.0.49" },
|
||||
"success": true,
|
||||
"model": "RDZ",
|
||||
"RESULT": {
|
||||
"TSLastUpdate": 1759138628,
|
||||
"info": {
|
||||
"datetime": "29/09/2025 12:37"
|
||||
},
|
||||
"status": {
|
||||
"ISP": "34.3 °C",
|
||||
"SSP": 47.0,
|
||||
"watert1": 32.1,
|
||||
"watert2": 32.0,
|
||||
"dhwt3": 46.8,
|
||||
"t4": 9.6,
|
||||
"watersetpoint": 43.0,
|
||||
"dhwsetpoint": 47.0,
|
||||
"heating": true,
|
||||
"cooling": false,
|
||||
"pwr": false,
|
||||
"san": false,
|
||||
"pump": true,
|
||||
"res": false,
|
||||
"standby": false,
|
||||
"sce": true,
|
||||
"alarm": {
|
||||
"status": false,
|
||||
"type": "",
|
||||
"label": ""
|
||||
},
|
||||
"worktime_pdc": 11614,
|
||||
"worktime_res": 593
|
||||
}
|
||||
}
|
||||
}
|
||||
```
|
||||
|
||||
### Status Fields
|
||||
|
||||
| Field | Type | Description |
|
||||
|-------|------|-------------|
|
||||
| `ISP` | string | Inlet Setpoint (e.g., "34.3 °C") |
|
||||
| `SSP` | float | System Setpoint |
|
||||
| `watert1` | float | Inflow water temperature |
|
||||
| `watert2` | float | Outflow water temperature |
|
||||
| `dhwt3` | float | Domestic hot water temperature |
|
||||
| `t4` | float | Outdoor temperature |
|
||||
| `watersetpoint` | float | Water temperature setpoint |
|
||||
| `dhwsetpoint` | float | DHW temperature setpoint |
|
||||
| `heating` | bool | Heating mode active |
|
||||
| `cooling` | bool | Cooling mode active |
|
||||
| `pwr` | bool | Compressor running |
|
||||
| `san` | bool | DHW mode active |
|
||||
| `pump` | bool | Circulation pump active |
|
||||
| `res` | bool | Auxiliary heater active |
|
||||
| `standby` | bool | Standby mode |
|
||||
| `sce` | bool | Smart Consumer Electronics |
|
||||
| `alarm.status` | bool | Alarm active |
|
||||
| `alarm.type` | string | Alarm type code |
|
||||
| `alarm.label` | string | Alarm description |
|
||||
| `worktime_pdc` | int | Compressor runtime (hours) |
|
||||
| `worktime_res` | int | Aux heater runtime (hours) |
|
||||
|
||||
### Set Parameter
|
||||
|
||||
Sets a heat pump parameter (temperature setpoint).
|
||||
|
||||
**Endpoint:**
|
||||
```
|
||||
POST /installedplugin/com.innova.pdc/<VERSION>/server/index.php?Action=SetParameter
|
||||
```
|
||||
|
||||
**Content-Type:** `application/x-www-form-urlencoded`
|
||||
|
||||
**Parameters:**
|
||||
|
||||
| Parameter | Type | Required | Description |
|
||||
|-----------|------|----------|-------------|
|
||||
| `Key` | string | Yes | Parameter name: `watersetpoint` or `dhwsetpoint` |
|
||||
| `Value` | string | Yes | Temperature value |
|
||||
| `manual` | string | Yes | Duration: `forever` or time-based |
|
||||
|
||||
**Example:**
|
||||
```bash
|
||||
curl -X POST "http://192.168.1.100/installedplugin/com.innova.pdc/2.0.10/server/index.php?Action=SetParameter" \
|
||||
-H "Content-Type: application/x-www-form-urlencoded" \
|
||||
-d "Key=watersetpoint&Value=45&manual=forever"
|
||||
```
|
||||
|
||||
**Response:** HTTP 200 on success
|
||||
|
||||
---
|
||||
|
||||
## Home Assistant Services
|
||||
|
||||
### rdz_innova_heatpump.set_water_setpoint
|
||||
|
||||
Manually set the heating water temperature setpoint.
|
||||
|
||||
**Service Data:**
|
||||
|
||||
| Attribute | Type | Required | Description |
|
||||
|-----------|------|----------|-------------|
|
||||
| `temperature` | float | Yes | Target temperature (35-60°C) |
|
||||
| `duration` | string | No | Duration: "forever" (default) or time-based |
|
||||
|
||||
**Example YAML:**
|
||||
```yaml
|
||||
service: rdz_innova_heatpump.set_water_setpoint
|
||||
data:
|
||||
temperature: 45
|
||||
duration: forever
|
||||
```
|
||||
|
||||
**Example Automation:**
|
||||
```yaml
|
||||
automation:
|
||||
- alias: "Set water temperature on schedule"
|
||||
trigger:
|
||||
- platform: time
|
||||
at: "06:00:00"
|
||||
action:
|
||||
- service: rdz_innova_heatpump.set_water_setpoint
|
||||
data:
|
||||
temperature: 45
|
||||
duration: forever
|
||||
```
|
||||
|
||||
---
|
||||
|
||||
## Entities
|
||||
|
||||
### Climate Entity
|
||||
|
||||
**Entity ID:** `climate.heat_pump_water_temperature`
|
||||
|
||||
**Attributes:**
|
||||
|
||||
| Attribute | Description |
|
||||
|-----------|-------------|
|
||||
| `current_temperature` | Current water temperature (T1) |
|
||||
| `temperature` | Target temperature setpoint |
|
||||
| `hvac_mode` | Current mode: `heat`, `cool`, `off` |
|
||||
| `hvac_action` | Current action: `heating`, `cooling`, `idle`, `off` |
|
||||
| `min_temp` | Minimum setpoint (35°C) |
|
||||
| `max_temp` | Maximum setpoint (60°C) |
|
||||
| `target_temp_step` | Temperature step (0.5°C) |
|
||||
|
||||
**Supported Features:**
|
||||
- `TARGET_TEMPERATURE`
|
||||
|
||||
**HVAC Modes:**
|
||||
- `heat` - Heating mode
|
||||
- `cool` - Cooling mode
|
||||
- `off` - Standby
|
||||
|
||||
### Water Heater Entity
|
||||
|
||||
**Entity ID:** `water_heater.heat_pump_dhw`
|
||||
|
||||
**Attributes:**
|
||||
|
||||
| Attribute | Description |
|
||||
|-----------|-------------|
|
||||
| `current_temperature` | Current DHW temperature (T3) |
|
||||
| `temperature` | Target DHW setpoint |
|
||||
| `operation_mode` | `on` when DHW active, `off` otherwise |
|
||||
| `min_temp` | Minimum setpoint (35°C) |
|
||||
| `max_temp` | Maximum setpoint (60°C) |
|
||||
|
||||
### Sensor Entities
|
||||
|
||||
| Entity ID | Unit | Description |
|
||||
|-----------|------|-------------|
|
||||
| `sensor.heat_pump_inlet_setpoint_temperature` | °C | ISP value |
|
||||
| `sensor.heat_pump_system_setpoint_temperature` | °C | SSP value |
|
||||
| `sensor.heat_pump_water_temperature_t1` | °C | Inflow temperature |
|
||||
| `sensor.heat_pump_outflow_temperature_t2` | °C | Outflow temperature |
|
||||
| `sensor.heat_pump_dhw_temperature_t3` | °C | DHW temperature |
|
||||
| `sensor.heat_pump_outdoor_temperature_t4` | °C | Outdoor temperature |
|
||||
| `sensor.heat_pump_water_setpoint` | °C | Water setpoint |
|
||||
| `sensor.heat_pump_dhw_setpoint` | °C | DHW setpoint |
|
||||
| `sensor.heat_pump_runtime` | h | Compressor hours |
|
||||
| `sensor.heat_pump_auxiliary_heater_runtime` | h | Aux heater hours |
|
||||
| `sensor.heat_pump_software_version` | - | Firmware version |
|
||||
|
||||
### Binary Sensor Entities
|
||||
|
||||
| Entity ID | Device Class | Description |
|
||||
|-----------|--------------|-------------|
|
||||
| `binary_sensor.heat_pump_heating` | heat | Heating mode |
|
||||
| `binary_sensor.heat_pump_cooling` | cold | Cooling mode |
|
||||
| `binary_sensor.heat_pump_working` | running | Compressor active |
|
||||
| `binary_sensor.heat_pump_dhw_mode` | running | DHW mode |
|
||||
| `binary_sensor.heat_pump_water_pump` | running | Pump active |
|
||||
| `binary_sensor.heat_pump_auxiliary_heater` | heat | Aux heater active |
|
||||
| `binary_sensor.heat_pump_standby` | power | Standby mode |
|
||||
| `binary_sensor.heat_pump_disabled_prod` | power | Production disabled |
|
||||
| `binary_sensor.heat_pump_sce` | power | SCE active |
|
||||
| `binary_sensor.heat_pump_alarm` | problem | Alarm active |
|
||||
|
||||
---
|
||||
|
||||
## Internal Data Structure
|
||||
|
||||
The coordinator maintains this internal data structure:
|
||||
|
||||
```python
|
||||
{
|
||||
"software_version": "3.0.49",
|
||||
"last_update": 1759138628,
|
||||
"datetime": "29/09/2025 12:37",
|
||||
|
||||
# Temperatures
|
||||
"inlet_setpoint_temp": 34.3,
|
||||
"system_setpoint_temp": 47.0,
|
||||
"water_temp_t1": 32.1,
|
||||
"water_temp_t2": 32.0,
|
||||
"dhw_temp_t3": 46.8,
|
||||
"outdoor_temp_t4": 9.6,
|
||||
"water_setpoint": 43.0,
|
||||
"dhw_setpoint": 47.0,
|
||||
"aux_heater": 0,
|
||||
|
||||
# States
|
||||
"is_heating": True,
|
||||
"is_cooling": False,
|
||||
"is_working": False,
|
||||
"is_dhw": False,
|
||||
"is_pump_active": True,
|
||||
"is_aux_heater": False,
|
||||
"is_standby": False,
|
||||
"disabled_prod": False,
|
||||
"sce": True,
|
||||
|
||||
# Runtimes
|
||||
"worktime_pdc": 11614,
|
||||
"worktime_res": 593,
|
||||
|
||||
# Alarms
|
||||
"has_alarm": False,
|
||||
"alarm_type": "",
|
||||
"alarm_label": ""
|
||||
}
|
||||
```
|
||||
|
||||
Access in custom code:
|
||||
```python
|
||||
coordinator = hass.data[DOMAIN][entry.entry_id]
|
||||
temp = coordinator.data.get("water_temp_t1")
|
||||
```
|
||||
Reference in New Issue
Block a user