12 KiB
CLAUDE.md - Boiler Auxiliary Heater Custom Integration
Purpose
Home Assistant custom integration (boiler_aux_heater) that manages an auxiliary electric heater mounted inside a DHW (Domestic Hot Water) boiler. The boiler's primary heat source is a heat pump; this integration controls a secondary resistive heater for:
- PV excess utilization - diverts surplus solar export to the heater instead of feeding back to the grid
- Boost heating - rapid hot water via bath boost timer with circulation pump control
- Preset-based temperature control - Normal, Eco, Boost, Sleep, Away presets with adjustable target temperatures
- Manual override - force heater ON for testing/emergency
Architecture Overview
The integration follows a coordinator pattern. BoilerAuxHeaterCoordinator is the central brain that:
- Listens to external entity state changes (boiler temp, grid power, relay state, heat pump aux heater)
- Reads internal entity states (switches, numbers) via direct references
- Runs decision logic to determine whether the heater relay should be ON or OFF
- Controls the physical relay via
switch.turn_on/switch.turn_offservice calls
All entities register themselves with the coordinator on async_added_to_hass and receive updates via a listener callback pattern (not HA's DataUpdateCoordinator).
External sensors (boiler temp, CT power x3, HP aux heater, relay state)
|
v (async_track_state_change_event + debounce)
BoilerAuxHeaterCoordinator._recalculate()
|
+-- reads switch states (manual_override, allow_usage, pv_excess_mode, boost_all_modes)
+-- reads number values (cut_off_temp, heater_power, pv_buffer, pv_target_temp, etc.)
+-- runs PV state machine (idle -> waiting_start -> active -> waiting_stop)
+-- computes main thermostat heating (hysteresis against climate target temp)
+-- computes final decision = manual_override OR (safety_ok AND (pv_heating OR bath_boost OR all_modes_boost))
|
v
Controls physical relay + notifies all entity listeners to update HA state
File Structure
| File | Purpose |
|---|---|
__init__.py |
Entry setup/unload, service registration (start_bath_boost), options update listener |
const.py |
All constants: domain, config keys, presets, number/switch definitions, tolerances |
coordinator.py |
BoilerAuxHeaterCoordinator - central logic, PV state machine, bath boost timer, relay control |
config_flow.py |
3-step config flow (core hardware, solar sensors, optional devices) + options flow |
climate.py |
BoilerAuxHeaterClimate - climate entity with presets, reads boiler temp from external sensor |
binary_sensor.py |
5 binary sensors: decision, pv_sufficient, running_on_pv, running_on_grid, bath_boost_active |
sensor.py |
Power sensors (total/pv/grid), energy sensors (Riemann sum integration), bath boost remaining timer |
switch.py |
4 config switches: manual_override, allow_usage, pv_excess_mode, boost_all_modes |
number.py |
13 configurable number entities (temperatures, thresholds, delays, power rating, etc.) |
button.py |
Bath boost start button (only created if circulation pump is configured) |
services.yaml |
Service definition for start_bath_boost |
strings.json |
UI strings for config flow and entity names |
translations/en.json |
English translations (mirrors strings.json + entity translations) |
manifest.json |
Integration manifest: domain=boiler_aux_heater, version=1.0.0, iot_class=local_push |
Key Classes
BoilerAuxHeaterCoordinator (coordinator.py)
Central state manager. Not a subclass of HA's DataUpdateCoordinator - uses a custom listener pattern instead.
State tracked:
pv_state- PV state machine:idle/waiting_to_start/active/waiting_to_stopbath_boost_active- whether bath boost is runningdecision- final ON/OFF decision for the relaypv_sufficient- whether PV export exceeds heater power needsrelay_is_on- current physical relay state (read from external entity)pv_shadow_heating- whether PV shadow thermostat logic wants heating
Entity registration: Internal entities call register_number(key, entity), register_switch(key, entity), register_climate(entity) during setup. The coordinator reads their values directly via get_number_value(key) and get_switch_state(key).
External state listening: Tracks state changes on configured external entities (boiler temp sensor, 3x CT power sensors, heater relay, optionally HP aux heater). Changes are debounced (1s) before triggering _recalculate().
PV State Machine:
idle->waiting_to_startwhen PV is sufficient (starts delay timer)waiting_to_start->activewhen start delay elapses and PV still sufficientwaiting_to_start->idleif PV drops before delayactive->waiting_to_stopwhen PV drops (starts stop delay timer)waiting_to_stop->activeif PV recovers before stop delaywaiting_to_stop->idlewhen stop delay elapses
Bath Boost Flow:
async_start_bath_boost()turns on circulation pump, sets climate to Boost preset, starts countdown timer_bath_boost_finished()callback turns off boost, restores pump schedule, turns off pump
BoilerAuxHeaterClimate (climate.py)
Single climate entity with:
- HVAC modes:
heat,off - Presets: Normal, Eco, Boost, Sleep, Away
- Uses
RestoreEntityto persist state across restarts current_temperaturereads from external boiler temp sensorhvac_actionreports HEATING when relay is on, IDLE when off- Setting a preset reads the target temp from the corresponding number entity
- Setting Boost preset activates
bath_boost_activeon coordinator; any other preset deactivates it
Energy Sensors (sensor.py)
BoilerEnergySensor uses internal Riemann sum integration (not HA's integration platform). It accumulates energy by multiplying the heater power rating by elapsed time on each coordinator update. Uses RestoreEntity + SensorStateClass.TOTAL_INCREASING for long-term tracking. Tracks total, PV-only, and grid-only energy separately.
Decision Logic (coordinator.py:_recalculate)
The heater relay is turned ON when:
decision = manual_override OR (
hp_aux_heater_off AND
allow_usage AND
boiler_temp < cut_off_temp AND
(
(pv_excess_mode AND pv_shadow_heating) OR
(bath_boost_active AND main_thermostat_heating) OR
(boost_all_modes AND main_thermostat_heating)
)
)
Safety defaults for unavailable sensors:
- Boiler temperature: defaults to
100.0(heater stays OFF - above any cut-off) - CT power sensors: default to
0.0(no export detected - PV won't trigger) - HP aux heater: treated as OFF if unavailable
PV sufficient calculation:
- When relay is OFF: each of the 3 CT phases must export more than
(buffer + heater_power) / 3 - When relay is ON (hysteresis): each phase must still be exporting (value <= 0)
Main thermostat heating (hysteresis):
- Turns ON when
boiler_temp < target - MAIN_COLD_TOLERANCE (4.0) - Turns OFF when
boiler_temp >= target + MAIN_HOT_TOLERANCE (0.0) - In tolerance band: maintains previous state
Config Flow (config_flow.py)
3-step wizard:
- Core Hardware: boiler temp sensor (temperature device class) + heater relay switch
- Solar Monitoring: 3x CT power sensors (power device class) for 3-phase grid monitoring
- Optional Devices: HP aux heater sensor (interlock), circulation pump switch (enables bath boost), pump schedule entity
Uses async_set_unique_id(DOMAIN) + _abort_if_unique_id_configured() - only one instance allowed.
Options flow allows reconfiguring all entity references post-setup.
Configurable Parameters (number entities, defined in const.py)
| Key | Default | Range | Purpose |
|---|---|---|---|
cut_off_temp |
60 | 40-85 C | Hard safety limit - heater stops above this |
temp_hysteresis |
4 | 1-15 C | Defined but not used in coordinator |
pv_target_temp |
55 | 40-70 C | Target temp for PV shadow thermostat |
pv_buffer |
100 | 0-1000 W | Extra export required before PV triggers |
heater_power |
4500 | 1500-9000 W | Heater wattage (used for PV threshold + energy calc) |
pv_start_delay |
60 | 1-300 s | Delay before activating PV mode |
pv_stop_delay |
60 | 1-300 s | Delay before deactivating PV mode |
temp_normal |
44 | 30-65 C | Normal preset target |
temp_eco |
40 | 30-60 C | Eco preset target |
temp_boost |
50 | 40-70 C | Boost preset target |
temp_sleep |
38 | 25-55 C | Sleep preset target |
temp_away |
35 | 20-50 C | Away preset target |
bath_boost_duration |
30 | 5-120 min | How long bath boost runs |
Mode Switches (switch entities, defined in const.py)
| Key | Default | Purpose |
|---|---|---|
manual_override |
OFF | Bypass all logic, force relay ON |
allow_usage |
ON | Master enable for aux heater |
pv_excess_mode |
ON | Enable PV excess diversion |
boost_all_modes |
OFF | Allow main thermostat heating to trigger relay (not just PV/bath boost) |
Known Issues / Design Notes
-
temp_hysteresisnumber entity is defined but unused - The coordinator uses hardcodedMAIN_COLD_TOLERANCE(4.0) andMAIN_HOT_TOLERANCE(0.0) instead of reading from this entity. -
Custom coordinator pattern - Does not extend
homeassistant.helpers.update_coordinator.DataUpdateCoordinator. Uses its own listener list and manual_notify_listeners(). This means no built-in polling fallback. -
Energy sensors use
time.monotonic()- Energy integration accuracy depends on how frequently_recalculatefires (debounced to 1s on external state changes). Long periods without state changes won't accumulate energy even if the relay is on. -
Single instance only - Config flow enforces one instance via unique_id. Multiple boiler setups would need code changes.
-
3-phase assumption - PV calculation assumes 3-phase power with per-phase CTs. All 3 phases must meet threshold independently (no sum/average).
-
Bath boost button conditional -
button.pyonly creates the bath boost button ifcirculation_pumpis configured. Thestart_bath_boostservice is always registered regardless. -
Relay control via service calls - The coordinator calls
switch.turn_on/turn_offservices to control the relay rather than directly setting state. Failure is caught and logged but doesn't retry. -
bath_boost_activeis toggled from two places - Bothclimate.async_set_preset_mode()(when selecting/deselecting Boost preset) andcoordinator.async_start_bath_boost()/_bath_boost_finished()modifybath_boost_active. The bath boost timer in the coordinator and the preset selection in the climate entity are loosely coupled. -
No
async_setup(YAML config) - Integration only supports config entries (UI setup), not YAML configuration. -
_enable_turn_on_off_backwards_compat = Falsein climate - opts out of HA 2024.x backwards compatibility forturn_on/turn_offbut doesn't declareClimateEntityFeature.TURN_ON | TURN_OFF.
Patterns Used
- RestoreEntity on climate, switch, number, and energy sensors for state persistence across restarts
- Entity registration with coordinator via
register_*()methods duringasync_added_to_hass - Data-driven entity creation from
NUMBER_DEFINITIONS,SWITCH_DEFINITIONS,BINARY_SENSOR_DEFINITIONSdicts - Debounced state change handling with
async_call_later(1s debounce) - Translation keys (