@@ -0,0 +1,42 @@
|
||||
- binary_sensor:
|
||||
|
||||
- name: "DHW: Use Boiler Aux Heater"
|
||||
unique_id: "dhw_config_use_boiler_aux_heater"
|
||||
state: >
|
||||
{% set manual_on = states('input_boolean.dhw_aux_heater_manual_override') == 'on' %}
|
||||
{% set hp_aux_off = states('sensor.heat_pump_auxiliary_heater') != 'on' %}
|
||||
{% set boiler_aux_allowed = states('input_boolean.dhw_allow_aux_heater_usage') == 'on' %}
|
||||
{% set boiler_temp_ok = states('sensor.boiler_temp')|float < states('input_number.dhw_aux_heater_cut_off_temperature_threshold')|float %}
|
||||
{# allowed checks if the resistance is permitted to run, mostly to check we're not running both boiler and HP resistance at the same time #}
|
||||
{% set allowed = hp_aux_off and boiler_aux_allowed and boiler_temp_ok %}
|
||||
{# here go various other conditions that influence the decision to run the boiler auxiliary heater #}
|
||||
{# PV Excess to boiler - now using shadow thermostat #}
|
||||
{% set pv_excess = states('input_boolean.dhw_use_excess_pv_for_aux_heater') == 'on' and
|
||||
state_attr('climate.dhw_pv_excess_heating', 'hvac_action') == 'heating' %}
|
||||
{% set thermostat_activity_boost = state_attr('climate.boiler_temperature','preset_mode') == 'activity' and
|
||||
state_attr('climate.boiler_temperature','hvac_action') == 'heating'%}
|
||||
{% set thermostat_normal_boost = states('input_boolean.dhw_allow_aux_heater_in_all_modes') == 'on' and
|
||||
state_attr('climate.boiler_temperature','hvac_action') == 'heating'%}
|
||||
{{ manual_on or
|
||||
(allowed and (
|
||||
pv_excess or
|
||||
thermostat_activity_boost or
|
||||
thermostat_normal_boost
|
||||
)) }}
|
||||
|
||||
- name: "DHW: PV Power Enough for Aux Heater "
|
||||
unique_id: "dhw_pv_power_enough_for_aux_heater"
|
||||
state: >
|
||||
{% set phase_buffer = states('input_number.dhw_pv_excess_usage_buffer')|float / 3 %}
|
||||
{% set phase_heater_power= states('input_number.dhw_aux_heater_power')|float /3 %}
|
||||
{% set turn_on_threshold = -1*(phase_buffer+phase_heater_power) %}
|
||||
{% if is_state('switch.boiler_heater_relay_switch_0', 'on') %}
|
||||
{{ states('sensor.deye_12_external_ct1_power')|float <= 0
|
||||
and states('sensor.deye_12_external_ct2_power')|float <= 0
|
||||
and states('sensor.deye_12_external_ct3_power')|float <= 0 }}
|
||||
{% else %}
|
||||
{{ states('sensor.deye_12_external_ct1_power')|float < turn_on_threshold
|
||||
and states('sensor.deye_12_external_ct2_power')|float < turn_on_threshold
|
||||
and states('sensor.deye_12_external_ct3_power')|float < turn_on_threshold }}
|
||||
{% endif %}
|
||||
device_class: power
|
||||
Reference in New Issue